Product Specific Information; Appliance Certification; Glass Specifications; Btu Specifications - Heat & Glo TRUE-36H-IFT Owner's Manual

Hide thumbs Also See for TRUE-36H-IFT:
Table of Contents

Advertisement

2

Product Specific Information

A. Appliance Certification
MODELS: TRUE-36G-IFT, TRUE-36H-IFT, TRUE-36S-IFT,
TRUE-42G-IFT, TRUE-42H-IFT, TRUE-42S-IFT
TRUE-50H-IFT, TRUE-50S-IFT
LABORATORY: Underwriters Laboratories, Inc. (UL)
TYPE: Direct Vent Heater
STANDARD: ANSI Z21.88-2017 • CSA 2.33-2017
This product is listed to ANSI standards for "Vented Gas
Fireplace Heaters" and applicable sections of "Gas Burn-
ing Heating Appliances for Manufactured Homes and
Recreational Vehicles", and "Gas Fired Appliances for
Use at High Altitudes".
NOTICE: This installation must conform with local codes.
In the absence of local codes you must comply with the
National Fuel Gas Code, ANSI Z223.1-latest edition in
the U.S.A. and the CAN/CGA B149 Installation Codes in
Canada.
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.
This appliance is tested and approved as either supplemen-
tal room heat or as a decorative appliance. It should not be
factored as primary heat in residential heating calculations.
Installation and service of this appliance should be performed by
qualified personnel. Hearth & Home Technologies recommends
HHT Factory Trained or NFI certified professionals.
B. Glass Specifications
This appliance is equipped with 5 mm ceramic glass with
an anti-reflective coating. Replace glass only with glass
with identical specifications. Please contact your dealer
for replacement glass.
6
Heat & Glo • TRUE-36-IFT, TRUE-42-IFT, TRUE-50-IFT Owner's Manual • 2461-981 Rev. J • 5/18
C. BTU Specifications
Models
(U.S. or Canada)
TRUE-36G-IFT
TRUE-36H-IFT
(0-2000 FT)
TRUE-36S-IFT
(NG)
TRUE-36G-IFT
TRUE-36H-IFT
(0-2000 FT)
TRUE-36S-IFT
(Propane)
TRUE-42G-IFT
TRUE-42H-IFT
(0-2000 FT)
TRUE-42S-IFT
(NG)
TRUE-42G-IFT
TRUE-42H-IFT
(0-2000 FT)
TRUE-42S-IFT
(Propane)
TRUE-50H-IFT
TRUE-50S-IFT
(0-2000 FT)
(NG)
TRUE-50H-IFT
TRUE-50S-IFT
(0-2000 FT)
(Propane)
Maximum
Minimum
Orifice
Input
Input
Size
BTU/h
BTU/h
(DMS)
45,500
28,000
#30
43,500
24,000
#47
55,500
30,500
#26
47,500
23,500
#45
65,000
36,000
#24
57,500
30,250
#43