Syslog Record Management - Panasonic VL-VN1800 Feature Manual

Video intercom system, control box
Hide thumbs Also See for VL-VN1800:
Table of Contents

Advertisement

[Programmable Items]
Outgoing intercom call
Date order
Time format
Conditions
[General]
SMDR data is not deleted even if the Control Box is reset.
SMDR data from a user is not deleted even if the user is deleted.
If the user is deleted while some SMDR data has not been output, the SMDR data may be output as
SMDR data for a new user added later.
If the Control Box is reset during a conversation, the call will not be recorded on SMDR.
[Output to a Telnet compatible Terminal Emulator]
In order to activate a connection to a terminal emulator, the IP address of the mother board, port number,
user ID ("SMDR"), and password must be entered.
If a terminal emulator user incorrectly enters the user ID or password 3 times consecutively, an alarm will
be sent and connection will not be possible for 10 minutes.
Through system programming, it is possible to assign the Control Box port number and password.
The terminal emulator application must be running constantly. If the application is terminated, call records
that occur after the termination will be recorded in the Control Box's memory. However, if the number of
call records exceeds the Control Box's capacity, older records will be deleted. Also, when the application
restarts or is reconnected, duplicated call records may be output.
[Using SMDR with applications]
SMDR data can also be monitored by applications. For more information, see your application's
documentation.
PC Programming Manual References
12.1 Control Box Configuration—[11-1] Maintenance—Main
Feature Manual References
5.1 Capacity of System Resources

2.6.1.2 Syslog Record Management

Description
By connecting the Control Box to a Syslog server over a LAN, it is possible to output local alarm information
(major alarms/minor alarms) to an external PC.
Item
Controls whether the outgoing intercom calls are recorded.
→ 12.1 Control Box Configuration—[11-1] Maintenance—Main
—SMDR—Print Information—Intercom Call
The date order is changeable: month/day/year, day/month/year,
year/month/day, year/day/month.
→ 12.1 Control Box Configuration—[11-1] Maintenance—Main
—SMDR—SMDR Format—Date Format
Controls whether time is displayed in 12-hour or 24-hour format.
→ 12.1 Control Box Configuration—[11-1] Maintenance—Main
—SMDR—SMDR Format—Time Format (12H / 24H)
2.6.1 Record Log Features