Heatilator CNXT4236IT-D Owner's Manual page 28

Table of Contents

Advertisement

E. Vent Diagrams
Top Vent - Horizontal Termination
Note: The CNXT series fireplaces can adapt to SLP series vent pipe,
if desired.
When venting off the top of the unit, use a DVP-2SL adapter and a
minimum 48 inch vertical section of SLP series vent pipe.
A DVP-SLP24 adapter may also be used with a 24 inch vertical
section of SLP series vent pipe.
After the 48 inch vertical section, the venting table rules must be
followed. The first 48 inch vertical section is NOT counted as part of
the vertical components in the table. It is still counted as part of the
overall maximum run. All venting table rules for the vent run must
still be followed.
Example: DVP pipe 3 ft. min. vertical = 11 ft. max. horizontal
SLP pipe 7 ft. min. vertical = 11 ft. max. horizontal
Top Vent - Horizontal Termination
One Elbow
Figure 7.4
28
Heatilator • CNXT4236IT-D, CNXT4842IT-D, CNXT4236IH-D, CNXT4842IH-D • 2360-900 Rev. i • 5/17
Note: For corner installations: A 6 inch (152
mm) section of straight pipe may need to
be attached to the appliance before a 90º
elbow, to allow the vent pipe to clear the top
standoffs.
H
1
WARNING
Fire Risk. Explosion Risk.
Do NOT pack insulation or other combustibles
between ceiling firestops.
• ALWAYS maintain specified clearances around
venting and firestop systems.
• Install wall shield and ceiling firestops as speci-
fied.
Failure to keep insulation or other material away
from vent pipe may cause fire.
WARNING
Fire Risk.
• When using DVP-HRC-SS and DVP-HRC-ZC-
SS termination caps on top vented fireplaces, a
6 inch minimum vertical vent section is required
before installing first elbow.
V
Minimum
1
Elbow only
1/2 ft.
1 ft.
1-1/2 ft.
2 ft.
V
+ H
1
1
H
= 25 ft. (7.6 m) Maximum
1
V
Minimum
1
Elbow only
1/2 ft.
152 mm
1 ft.
305 mm
V
1-1/2 ft.
457 mm
1
2 ft.
610 mm
2-1/2 ft.
762 mm
3 ft.
914 mm
4 ft.
6 ft.
V
+ H
1
1
H
= 25 ft. (7.6 m) Maximum
1
CNXT4236 Series
H
Maximum
1
2 ft.
610 mm
152 mm
6 ft.
1.8 m
305 mm
11 ft.
3.4 m
457 mm
18 ft.
5.5 m
610 mm
25 ft.
7.6 m
= 40 ft. (12.2 m) Maximum
CNXT4842 Series
H
Maximum
1
2 ft.
610 mm
2 ft.
610 mm
4 ft.
1.2 m
6 ft.
1.8 m
8 ft.
2.4 m
8 ft.
2.4 m
12 ft.
3.7 m
1.2 m
20 ft.
6.1 m
1.9 m
25 ft.
7.6 m
= 40 ft. (12.2 m) Maximum