Service And Maintenance Procedures - Carrier 59MN7B Installation, Start-Up, Operating And Service And Maintenance Instructions

Modulating 4-way multipoise condensing gas furnace
Table of Contents

Advertisement

Table 20 - - Orifice Size and Manifold Pressure (In. W.C.) for Gas Input Rate (Continued)
(TABULATED DATA BASED ON 20,200 BTUH MAX-HEAT / 8,000 BTUH MIN-HEAT PER BURNER,
ALTITUDE
RANGE
ft (m)
7001
(2134)
to
8000
(2438)
8001
(2439)
to
9000
(2743)
9001
(2744)
to
10000
(3048)
* Orifice numbers shown in BOLD are factory-installed.
SERVICE AND MAINTENANCE
PROCEDURES
Untrained personnel can perform basic maintenance functions
such as cleaning and replacing air filters. All other operations
must be performed by trained service personnel. A qualified
service person should inspect the furnace once a year.
WARNING
!
FIRE, INJURY OR DEATH HAZARD
Failure to follow this warning could result in personal
injury, death and/or property damage.
The ability to properly perform maintenance on this
equipment requires certain knowledge, mechanical skills,
tools, and equipment. If you do not possess these, do not
attempt to perform any service and maintenance on this
equipment other than those procedures recommended in the
Owner's Manual.
CAUTION
!
ENVIRONMENTAL HAZARD
Failure to follow this caution may result in environmental
pollution.
Remove and recycle all components or materials (i.e. oil,
refrigerant, control board, etc.) before unit final disposal.
To Be Used with Modulating Furnaces 59MN7B060C21- -20 Only
DERATED 2%/1000 FT (305M) ABOVE SEA LEVEL)
A
V
G
.
G
A
S
HEAT VALUE
0.58
AT ALTITUDE
Orifice Mnfld Press Orifice Mnfld Press Orifice Mnfld Press Orifice Mnfld Press
(Btu/cu ft)
No.
Max/Min
650
42
3.4 /0.55
675
42
3.2 /0.50
700
43
3.6 /0.55
725
43
3.4 /0.55
750
44
3.6 /0.55
775
44
3.4 /0.55
800
44
3.2 /0.50
825
46
3.8 /0.60
625
42
3.4 /0.55
650
42
3.2 /0.50
675
43
3.6 /0.55
700
44
3.8 /0.60
725
44
3.6 /0.55
750
44
3.3 /0.50
775
45
3.8 /0.60
600
42
3.4 /0.55
625
43
3.8 /0.60
650
43
3.5 /0.55
675
44
3.8 /0.60
700
44
3.5 /0.55
725
44
3.3 /0.50
S
P
E
C
F I
C I
G
R
A
V
T I
Y
O
F
N
A
0.60
No.
Max/Min
No.
42
3.6 /0.55
42
42
3.3 /0.50
42
43
3.7 /0.60
42
43
3.5 /0.55
43
44
3.7 /0.60
43
44
3.5 /0.55
44
44
3.3 /0.50
44
45
3.7 /0.60
44
42
3.5 /0.55
42
42
3.3 /0.50
42
43
3.7 /0.60
43
43
3.4 /0.55
43
44
3.7 /0.60
44
44
3.4 /0.55
44
44
3.2 /0.50
44
42
3.5 /0.55
42
42
3.2 /0.50
42
43
3.6 /0.55
43
43
3.4 /0.55
43
44
3.6 /0.55
44
44
3.4 /0.55
44
WARNING
!
ELECTRICAL SHOCK, FIRE OR EXPLOSION
HAZARD
Failure to follow this warning could result in personal
injury or death, or property damage.
Before installing, modifying, or servicing system, main
electrical disconnect switch must be in the OFF position and
install a lockout tag.
disconnect switch. Lock out and tag switch with a suitable
warning label.
Verify proper operation after servicing.
Always reinstall access doors after completing service and
maintenance.
CAUTION
!
ELECTRICAL OPERATION HAZARD
Failure to follow this caution may result in improper
furnace operation or failure of furnace.
Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and dangerous
operation.
General
These instructions are written as if the furnace is installed in an
upflow application. An upflow furnace application is where the
blower is located below the combustion and controls section of the
furnace, and conditioned air is discharged upward. Since this
79
T
U
R
A
L
G
A
S
0.62
0.64
Max/Min
No.
Max/Min
3.7 /0.60
42
3.8 /0.60
3.4 /0.55
42
3.5 /0.55
3.2 /0.50
42
3.3 /0.50
3.6 /0.55
43
3.7 /0.60
3.4 /0.55
43
3.5 /0.55
3.6 /0.55
44
3.7 /0.60
3.4 /0.55
44
3.5 /0.55
3.2 /0.50
44
3.3 /0.50
3.7 /0.55
42
3.8 /0.60
3.4 /0.55
42
3.5 /0.55
3.8 /0.60
42
3.2 /0.50
3.6 /0.55
43
3.7 /0.55
3.8 /0.60
43
3.4 /0.55
3.5 /0.55
44
3.7 /0.55
3.3 /0.50
44
3.4 /0.55
3.6 /0.55
42
3.8 /0.60
3.3 /0.55
42
3.5 /0.55
3.8 /0.60
42
3.2 /0.50
3.5 /0.55
43
3.6 /0.55
3.7 /0.60
44
3.8 /0.60
3.5 /0.55
44
3.6 /0.55
There may be more than one
A11621B