Electrical Connections - Carrier 59MN7B Installation, Start-Up, Operating And Service And Maintenance Instructions

Modulating 4-way multipoise condensing gas furnace
Table of Contents

Advertisement

GAS
SUPPLY
MANUAL
SHUT OFF
VALVE
(REQUIRED)
UNION
SEDIMENT
TRAP
Fig. 30 - - Typical Gas Pipe Arrangement
A 1/8- -in. (3 mm) NPT plugged tapping, accessible for test gauge
connection, MUST be installed immediately upstream of gas
supply connection to furnace and downstream of manual
equipment shutoff valve.
Piping should be pressure and leak tested in accordance with the
current addition of the NFGC in the United States, local, and
national plumbing and gas codes before the furnace has been
connected. Refer to current edition of NSCNGPIC in Canada.
After all connections have been made, purge lines and check for
leakage at furnace prior to operating furnace.
NOTE:
The furnace gas control valve inlet pressure tap
connection is suitable to use as test gauge connection providing
test pressure DOES NOT exceed maximum 0.5 psig (14- -In. W.C.)
stated on gas control valve. See Fig. 60.
If pressure exceeds 0.5 psig (14- -In. W.C.), gas supply pipe must
be disconnected from furnace and capped before and during
supply pipe pressure test. If test pressure is equal to or less than 0.5
psig (14- -In. W.C.), turn off electric shutoff switch located on
furnace gas control valve and accessible manual equipment shutoff
valve before and during supply pipe pressure test. After all
connections have been made, purge lines and check for leakage at
furnace prior to operating furnace.
The gas supply pressure shall be within the maximum and
minimum inlet supply pressures marked on the rating plate with
the furnace burners ON and OFF.
Gas entry can be from left or right side, or top panel. See Figs. 31
and 32.
Gas Pipe Grommet
For direct vent (2-pipe) applications, the knockout for the gas pipe
must be sealed to prevent air leakage. Remove the knockout,
install the grommet in the knockout, then insert the gas pipe. The
grommet is included in the loose parts bag. See Fig. 31.
FRONT
NOTE: Union may be inside the
vestibule where permitted by
local codes.
A11035
Left Side Gas Entry. Gas Pipe
Grommet Required For Direct
Vent Applications.
Fig. 31 - - Gas Entry
Fig. 32 - - Alternate Gas and Electric Entry
NOTE: Top plate may be field drilled for alternate gas and
115 VAC electric entry.

ELECTRICAL CONNECTIONS

WARNING
!
ELECTRICAL SHOCK, FIRE OR EXPLOSION
HAZARD
Failure to follow safety warnings could result in
dangerous operation, serious injury, death or property
damage.
Improper servicing could result in dangerous operation,
serious injury, death or property damage.
- - Before servicing, disconnect all electrical power to
furnace.
- - When servicing controls, label all wires prior to
disconnection. Reconnect wires correctly.
- - Verify proper operation after servicing.
- - Always reinstall access doors after completing service
and maintenance.
33
Gas Pipe Grommet Required
For Direct Vent Applications
1 1/2 inch for Gas
7/8 inch for 115 VAC Electric
A11338
A170125