3. Removal of Electrical Components ASSY

Procedure
Step
1. Remove the drip proof
plate.
Remove the 3 screws
1
of the drip proof plate.
Remove the drip proof
2
plate.
2. Remove the electrical
components ASSY.
Disconnect all the
1
harnesses.
2
Remove the 2 screws
of electrical
components ASSY.
Remove the electrical
3
components ASSY.
Removal Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Removal of Electrical Components ASSY
Points
(R1857)
(R1858)
(R1859)