Download Print this page

Removal Of Partition Plate - Daikin RE25JV1 Removal Procedure

2.5/3.5 kw class
Hide thumbs Also See for RE25JV1:

Advertisement

Si01-752

6. Removal of Partition Plate

Procedure
Step
Disengage the
1
compressor lead wires
from the wire clip.
Remove the 2 screws
2
of the partition plate.
Pull and remove the
3
partition plate.
When restoring the
4
partition plate, put the
hook into the bottom
frame.
Removal Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Bottom
frame
Hook
Compressor lead wire
Wire clip
(R12800)
(R1871)
(R12801)
(R1873)
Removal of Partition Plate
Points
9