Technical Data - WAGNER WallPerfect Flexio 580 I-Spray Manual

Hide thumbs Also See for WallPerfect Flexio 580 I-Spray:
Table of Contents

Advertisement

Available languages

Available languages

Flexio 580 I-Spray
problem
Device does not
function

24. technical Data

Max. viscosity (Interior wall paint/WallPerfect
I-Spray spray attachment):
Power source:
Current strength:
Atomizing output:
Max. flow rate (Interior wall paint/WallPerfect
I-Spray spray attachment):
Protection class:
Sound pressure level*:
Sound pressure output*:
Oscillation level**:
Weight:
* Measured in accordance with EN 50144-2-7:2000
** Measured in accordance with EN 60745-1
information about the oscillation level
The specified oscillation level has been measured according to a standard test
procedure and can be used to compare against electric tools.
The oscillation level is also for determining an initial assessment of the vibrational strain.
Attention! The vibration emission value can differ from the specified value when the
electric tool is actually in use, depending on how the electric tool is being used. It is
necessary to specify safety measures to protect the operating personnel. These measures
are based on an estimated shutdown during the actual conditions of use (all parts of the
operating cycle are taken into consideration here, for example periods when the electric
tool is switched off, and, when it is switched on but running without any load).
Cause
D evice overheated
technical Data
remedy
➞ Unplug the power
plug, let the device
cool down approx. 30
minutes, check the air
filter, do not cover the
intake slots
4000 mPas
110 V
, 60 Hz
~
5 A
100 W (Level I), 200 W (Level II)
500 ml/min
I
74 dB (A); Uncertainty K = 4 dB
87 dB (A); Uncertainty K = 4 dB
< 2.5 m/s²; Uncertainty K = 1.5 m/s²
1.9 kg
GB
55