Technical Data - WAGNER SUPER FINISH 21 PRO Operating Manual

Airless high-pressure spraying unit
Hide thumbs Also See for SUPER FINISH 21 PRO:
Table of Contents

Advertisement

Super Finish 21 Pro
3.4

TECHNICAL DATA

Voltage :
Fuses :
Unit connecting line :
Max. current consumption:
Degree of protection :
Rated input of device:
Max. operating pressure :
Max. volume flow :
Volume flow at 12 MPa
(120 bar) with water :
Max. temperature of the
coating material :
Max. viscosity :
Empty weight :
Hydraulic oil filling quantity :
Max. vibration at the spraygun :
Max. sound pressure level:
*Place of measurement: 1 m distance from unit and 1.60 m above floor, 12 MPa (120 bar)
operating pressure, reverberant floor
Transportation in vehicle
Secure the unit in the vehicle by means of suitable fasteners.
The device can be placed on its side if necessary. In this case,
please ensure that no attachments can be damaged. Atten-
tion: Paint or solvent residues can escape from the connec-
tions!
230-240 V
230-240 V AC, 50 Hz
8 A time-lag
6 m long, 3 x 1.0 mm²
4.2 A
IP 54
900 W
20.7 MPa (207 bar)
2.1 l/min
1.6 l/min
43 °C
15,000 mPas
23.6 kg
0.96 liter
lower than 2.5 m/s²
77 dB (A)*
GENERAL VIEW OF APPLICATION/ DESCRIPTION OF UNIT
110 V
110-120 V AC, 50 Hz
16 A time-lag
6 m long, 3 x 1.5 mm²
9.0 A
850 W
1.8 l/min
23.9 kg
EN