Indoor Air Quality - Lennox Energence LGH Manual

Table of Contents

Advertisement

FEAT UR ES AND BENEF ITS
BLOWER
J
J
A wide selection of supply air blower options are available
to meet a variety of airflow requirements
Motor
• Overload protected, equipped with ball bearings
• Belt drive motors are offered on all models and are
available in several different sizes to maximize air
performance
Supply Air Blower
• Forward curved blades
• Double inlet
• Blower wheel statically and dynamically balanced
• Ball bearings
• Adjustable pulley (allows speed change)
• Blower assembly slides out of unit for servicing
• Grease fittings furnished
Required Selections
• Specify motor output and drive kit number when base
unit is ordered
• See Drive Kit Specifications Table
Options/Accessories
Factory Installed
Blower Belt Auto-Tensioner
• Provides proper tension to belt drive blower belt without
the need for regular adjustments
• Maintains airflow and proper performance
ELECTRICAL
SmartWire™ System
• Keyed and color-coded wiring connectors prevent
miswiring
• Wire coloring scheme is standardized across all models
• Each connection is intuitively labeled to make
troubleshooting and servicing quick and easy

INDOOR AIR QUALITY

K
K
Air Filters
• Disposable 51 mm filters furnished as standard
Options/Accessories
Factory or Field Installed
Healthy Climate
High Efficiency Air Filters
®
• Disposable MERV 8 or MERV 13 (Minimum Efficiency
Reporting Value based on ASHRAE 52.2) efficiency 51
mm pleated filters
Replacement Filter Media Kit With Frame
• Replaces existing pleated filter media
• Includes washable metal mesh screen and metal frame
with clip for holding replaceable non-pleated filter
Field Installed
Healthy Climate
UVC Germicidal Lamps
®
• Germicidal lamps emit ultra-violet (UV-C) energy, which
has been proven to be effective in reducing microbes
such as viruses, bacteria, yeasts, and molds
• This process either destroys the organism or controls its
ability to reproduce
• UV-C energy greatly reduces the growth and proliferation
of mold and other bioaerosols (bacteria and viruses) on
illuminated surfaces (particularly coil and drain pan)
• Field installed in the blower/evaporator coil section
• Magnetic safety interlock terminates power when
access panels are removed
• All necessary hardware for installation is included
• Lamps operate on 220V-1ph power supply
NOTE - Step-down transformer must be field supplied for
field installation for 380/420V primary to 220V
secondary.
Indoor Air Quality (CO2) Sensors
• Monitors CO2 levels, reports to the Prodigy
controller which adjusts economizer dampers as needed
Energence
Packaged Gas / Electric 45.7 to 88 kW - 50 Hz/ Page 7
®
unit
®

Advertisement

Table of Contents
loading

Table of Contents