Download Print this page

Safety Notes; General Safety Instructions - Siemens SINAMICS S120 Operating Instructions Manual

Cabinet modules. option l34. parameterizing the output-side circuit breaker
Hide thumbs Also See for SINAMICS S120:

Advertisement

Safety notes

1.1

General safety instructions

Electric shock and danger to life due to other energy sources
Touching live components can result in death or serious injury.
• Only work on electrical equipment if you are appropriately qualified.
• Always observe the country-specific safety rules for all work.
Generally, the following steps apply when establishing safety:
1. Prepare for disconnection. Notify all those who will be affected by the procedure.
2. Isolate the drive system from the power supply and take measures to prevent it being
3. Wait until the discharge time specified on the warning labels has elapsed.
4. Check that there is no voltage between any of the power connections, and between any of
5. Check that every auxiliary circuit is de-energized.
6. Ensure that the motors cannot move.
7. Identify all other dangerous energy sources, e.g. compressed air, hydraulic systems or
8. Check that the correct drive system is completely locked.
After you have completed the work, restore the operational readiness by following the
above steps in the reverse order.
Electric shock if there is no ground connection
For missing or incorrectly implemented protective conductor connection for devices with
protection class I, high voltages can be present at open, exposed parts, which when
touched, can result in death or severe injury.
• Ground the device in compliance with the applicable regulations.
Option L34 parameterizing the circuit breaker on the output side
Operating Instructions, 03/2021, A5E02914106A
WARNING
switched back on again.
the power connections and the protective conductor connection.
water. Switch the energy sources to a safe state.
WARNING
1
5

Advertisement