Ensure that you have an ESD grounding strap.
If not already installed, install the power supplies in the router. See Maintain the PTX10001-36MR Power Supplies.
NOTE:
Each power supply must be connected to a dedicated power source outlet.
To connect AC power to a PTX10001-36MR:
1. Wrap and fasten one end of the ESD wrist strap around your bare wrist, and connect the other end of the strap to the
ESD point on the device.
2. Ensure that the power supplies are fully inserted in the chassis and the latches are secure.
3. Locate the power cord or cords shipped with the PTX10001-36MR; the cords have plugs appropriate for your
geographical location. See PTX10001-36MR Power Cord Specifications.
WARNING:
where people could trip on it.
4. Connect each power supply to the power sources. Insert the coupler end of the power cord into the AC power cord
inlet on the AC power supply faceplate (see
NOTE:
The coupler end of the power cord model is APP-400.
Figure 10: Connect an AC Power Cord to the PTX10001-36MR
5. If the AC power source outlet has a power switch, set it to the off (O) position.
NOTE:
The device powers on as soon as power is provided to the power supply. There is no power switch
on the device.
Ensure that the power cord does not block access to router components or drape
Figure
10).