INDUCTION COOKTOP ERROR CODES
Error
Error
Code
E 00
Overvoltage
E 01
Left key error
E 02
Right key error
E 03
Center key error
E 04
Data flash error
E 05
LIN communication error
E 06
Controller options error
E 07
TC temperature too high
Invalid generator
E 08
configuration
Coil assembly 1 temperature
E 09
too high
Coil assembly 2 temperature
E 10
too high
Coil assembly 3 temperature
E 11
too high
Coil assembly 4 temperature
E 12
too high
Coil assembly 5 temperature
E 13
too high
E 14
Configuration implausible
Power supply error on
E 15
generator
829191 REVA

INDUCTION ERROR CODES

Component
Error Description
Over voltage detection from the
Generator
induction generator.
Key error on the left secondary
Left secondary
Key error on the right secondary 1
Right secondary
Key error on the primary
Primary
Not a shown error. A cyclic reset
of the controller
All components
No response from the generator.
Primary
Cable or generator issue.
Not currently used
Primary is too hot.
Primary
Generator
Generator
Generator
Generator
Generator
Generator
0x13 = CRC error of
configuration data.
Generator
0x30 = Configuration values
implausible.
Generator voltage too low.
Generator
75
30" and 36" Induction Range
service.subzero.com
Service Instruction
1
Check voltage supply.
2
Replace induction generator.
1
Reseat wire harnesses.
2
Replace the left secondary control
board.
Reseat wire harnesses.
2
Replace the right secondary control
board.
1
Reseat wire harnesses.
2
Replace the primary control board.
1
Cycle the unit electrical supply.
2
Replace the primary and secondary
control boards.
3
Replace the induction generator.
1
Reseat the wire harnesses.
2
Replace the induction generator.
1
Check airflow for blockage.
2
Replace primary control board.
1
Cycle the unit electrical supply.
2
Replace the induction generator.
1
Replace the coil assembly.
2
Replace the induction generator.
1
Replace the coil assembly.
2
Replace the induction generator.
1
Replace the coil assembly.
2
Replace the induction generator.
1
Replace the coil assembly.
2
Replace the induction generator.
1
Replace the coil assembly.
2
Replace the induction generator.
1
Cycle the unit electrical supply.
2
Replace the induction generator.
1
Check voltage supply.
2
Replace induction generator.