Troubleshooting
Induction Range Error Codes
Error
Shown Phrase
Code
2522
eMDLSwitchCircuitFault
2631
eDoorSwitchCircuitFault
2632
eDoorSwitchCircuitFault
2931
eLineVoltageSenseCircuitFault
2932
eLineVoltageSenseCircuitFault
2A31
eLVM_HVMCommunFault
2A32
eLVM_HVMCommunFault
2B31
eHVMMonitorCircuitFault
2B32
eHVMMonitorCircuitFault
2C21
ePCMRs485NetworkFault
2C22
ePCMRs485NetworkFault
3031
eTemperatureProbeShorted
3032
eTemperatureProbeShorted
3121
eRTDShorted
3122
eRTDShorted
3221
eRTDOpen
3222
eRTDOpen
3311
eTCOOpen
3312
eTCOOpen
4021
eBakeElementLoadMissing
829191 REVA
INDUCTION RANGE ERROR CODES
PRI
Component
2
Left oven
3
Right oven
3
Left oven
3
Right oven
3
Left oven
2
Right oven
2
Left oven
3
Right oven
3
Left oven
2
Right oven
2
Left oven
3
Right oven
3
Left oven
2
Right oven
2
Left oven
2
Right oven
2
Left oven
1
Right oven
1
Left oven
2
69
30" and 36" Induction Range
Error Description
Service Instruction
1
2
The door switch circuit on
1
the relay board is
2
malfunctioning.
1
2
The incoming voltage
1
level detection circuit on
the relay board is
1
malfunctioning.
No communications or
1
too many bad packets
between the two
1
processors on the relay
board.
One of the output monitor
1
circuits on the relay board
is malfunctioning.
1
The relay board detects
1
an error with the RS485
2
network.
1
2
The temperature probe is
1
broken. The socket is
2
broken or wired wrong.
Probe circuit reporting
1
below 1k Ω.
2
The RTD is broken or
1
wired wrong. RTD circuit
2
reporting below 825 Ω.
1
2
The RTD is broken or
1
wired wrong. RTD circuit
2
reporting below 3049 Ω.
1
2
The TCO has opened due
1
to excessive temperature
2
or a wiring issue.
1
2
No load detected when
1
the element is turned on.
service.subzero.com
Check the MDL circuit.
Replace the relay board.
Check the door switch circuit.
Replace the relay board.
Check the door switch circuit.
Replace the relay board.
Replace the relay board.
Replace the relay board.
Replace the relay board.
Replace the relay board.
Replace the relay board.
Replace the relay board.
Check the RS485 circuitry.
Replace the relay board.
Check the RS485 circuitry.
Replace the relay board.
Check the probe circuitry.
Replace the relay board.
Check the probe circuitry.
Replace the relay board.
Check the RTD circuit.
Replace the relay board.
Check the RTD circuit.
Replace the relay board.
Check the RTD circuit.
Replace the relay board.
Check the RTD circuit.
Replace the relay board.
Check the TCO circuit.
Replace the TCO.
Check the TCO circuit.
Replace oven TCO.
Check the bake element.

Advertisement