6. SPECIFICATIONS OF ELECTRICAL PARTS

Outdoor Unit
No.
Parts name
1
Compressor
2
Outdoor fan motor
3
Reactor
4
Reactor
5
PMV coil
6
P.C. board(Main PCB)
7
P.C. board(Control PCB)
8
P.C. board(Display PCB)
9
Fuse (Mounted on P.C. board MCC-1645)
10
Fuse
11
Fuse (Mounted on P.C. board MCC-1645、
MCC-1665)
12
Outdoor temp. sensor (TO sensor)
13
Discharge temp. sensor (TD sensor)
14
Temp. sensor at A room gas side (TGA-
sensor)
15
Temp. sensor at B room gas side (TGB-
sensor)
16
Temp. sensor at C room gas side (TGC-
sensor) *only 3M series
17
Compressor thermo.
18
Terminal block (3P)
*only 2M series
19
Terminal block (6P)
High-pressure SW
20
Model name
DX136A1T-40N
2M21,3M41 series
3M31 series
DX151A1T-30N
ICF-340-A70-1
CH-57-WL
CH-76-VK
PQ-M10012-000313
MCC-1645
MCC-1665
MCC-1646
CS-12AL
ACB-1UB177W
- 27 -
Rating
3-Phases (4-Poles);1100W
3-Phases (4-Poles);1100W
Output 70W
10mH、16A
9.9mH、1A
DC12V
AC220-240V
DC 5V
DC 5V
AC250V、25A
AC250V、6.3A
AC250V、3.15A
10kΩ (25℃)
50kΩ (25℃)
10kΩ (25℃)
10kΩ (25℃)
10kΩ (25℃)
ON:90℃、OFF:125℃
AC250V、20A
AC600V、30A
OFF:4.5MPa