Toshiba RAS-2M21U2ACVG-SG Service Manual page 13

Table of Contents

Advertisement

RAS-3M41U2ACVG-SG
Operation mode : Cooling
Current limit : none, 11.0A and 8.5A
220V
Power supply voltage:
Indoor unit
Operating
status
A
B
C
3 Units
10
10
10
13
10
10
18
10
10
13
13
10
18
13
10
13
13
13
Power supply voltage:
230V
Indoor unit
Operating
status
A
B
C
3 Units
10
10
10
13
10
10
18
10
10
13
13
10
18
13
10
13
13
13
Power supply voltage:
240V
Indoor unit
Operating
status
A
B
C
3 Units
10
10
10
13
10
10
18
10
10
13
13
10
18
13
10
13
13
13
Unit capacity
ΣkBTU
A
B
C
30
1.44
1.43
1.43
33
1.70
1.30
1.30
38
1.92
1.19
1.19
36
1.55
1.55
1.20
41
1.77
1.43
1.10
39
1.44
1.43
1.43
Unit capacity
ΣkBTU
A
B
C
30
1.44
1.43
1.43
33
1.70
1.30
1.30
38
1.92
1.19
1.19
36
1.55
1.55
1.20
41
1.77
1.43
1.10
39
1.44
1.43
1.43
Unit capacity
ΣkBTU
A
B
C
30
1.44
1.43
1.43
33
1.70
1.30
1.30
38
1.92
1.19
1.19
36
1.55
1.55
1.20
41
1.77
1.43
1.10
39
1.44
1.43
1.43
Cooling capacity (kW)
Power consumption (W)
Min
Rated
Max
Min
Rated
2.15
4.30
7.50
356
754
2.15
4.30
7.50
356
752
2.15
4.30
7.50
356
752
2.15
4.30
7.50
356
752
2.15
4.30
7.50
356
752
2.15
4.30
7.50
356
752
Cooling capacity (kW)
Power consumption (W)
Min
Rated
Max
Min
Rated
2.15
4.30
7.50
356
754
2.15
4.30
7.50
356
752
2.15
4.30
7.50
356
752
2.15
4.30
7.50
356
752
2.15
4.30
7.50
356
752
2.15
4.30
7.50
356
752
Cooling capacity (kW)
Power consumption (W)
Min
Rated
Max
Min
Rated
2.15
4.30
7.50
356
754
2.15
4.30
7.50
356
752
2.15
4.30
7.50
356
752
2.15
4.30
7.50
356
752
2.15
4.30
7.50
356
752
2.15
4.30
7.50
356
752
- 13 -
Operating current (A)
Max
Min
Rated
Max
1800
2.14
3.68
8.50
1795
2.14
3.68
8.47
1790
2.14
3.68
8.45
1795
2.14
3.68
8.47
1790
2.14
3.68
8.45
1790
2.14
3.68
8.45
Operating current (A)
Max
Min
Rated
Max
1800
2.05
3.54
8.13
1795
2.04
3.53
8.13
1790
2.04
3.53
8.10
1795
2.04
3.53
8.13
1790
2.04
3.53
8.10
1790
2.04
3.53
8.10
Operating current (A)
Max
Min
Rated
Max
1800
1.96
3.38
7.79
1795
1.96
3.37
7.78
1790
1.96
3.37
7.75
1795
1.96
3.37
7.78
1790
1.96
3.37
7.75
1790
1.96
3.37
7.75
EER
Rated
5.70
5.72
5.72
5.72
5.72
5.72
EER
Rated
5.70
5.72
5.72
5.72
5.72
5.72
EER
Rated
5.70
5.72
5.72
5.72
5.72
5.72

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ras-3m31u2acvg-sgRas-3m41u2acvg-sg

Table of Contents