Daikin FTV-A Series Engineering Data page 38

Split unit air conditioner wall mounted
Table of Contents

Advertisement

Wiring Diagram
Model : FTV85PS
NOTATION:
FM : FAN MOTOR
AS : AIR SWING MOTOR
TH1 : INDOOR COIL THERMISTOR
TH2 : ROOM THERMISTOR
: FIELD WIRING
G/Y
TO OUTDOOR UNIT
Outdoor Unit
Model : RC85A
36
BLACK
WHITE
BROWN
FM
BLACK (LIVE)
RED (FAN CAP)
WHITE (NEUTRAL)
COMP
COMP
N1
N
L
N
CN_STP
CN_FAN FB
CN_FAN
L
CN_PGRM
CN_WIR
CN_DSP
L
WIRED
(POWER
N
ACCESSORY
SUPPLY)
E
(OPTIONAL)
AS
TH1
TH2
DISPLAY BOARD
AW* WI-FI
ADAPTOR
R08024134385B
3P553098-1