Daikin FTV-A Series Engineering Data page 16

Split unit air conditioner wall mounted
Table of Contents

Advertisement

Installation Guideline
1) Attach the drain hose to the underside of the refrigerant
pipes with adhesive vinyl tape.
2) Be sure to connect the drain hose to the drain port in place
of a drain plug.
3) Shape the refrigerant pipe along the pipe path marking on
the mounting plate.
4) Pass drain hose and refrigerant pipes through the wall
hole, then set the indoor unit on mounting plate hooks,
using the markings at the top of indoor unit as a guide.
5) Pull in the inter-unit wiring.
6) Connect the inter-unit piping.
Drain hose
Caulk this hole
with putty or
caulking material
7) Wrap the refrigerant pipes and drain hose together with
insulation tape as right figure.
8) Take extra care while going through activities so that the
interconnecting wires do not damaged by indoor unit, press
the bottom edge of indoor unit with both hands until it is firmly
caught by the mounting plate hooks. Secure indoor unit to the
mounting plate with the screws (M4 × 12L).
Wall embedded piping.
Follow the instructions given under
Left-side, left-back, or left-bottom piping
1) Insert the drain hose to this depth so it won't be pulled out of
the drain pipe.
The indoor unit must be installed in such a way so as to prevent short circuit of the cool discharged air with the
hot return air. Please follow the installation clearance shown in the figure. Do not place the indoor unit where there
could be direct sunlight shining on it. Also, this location must be suitable for piping and drainage, and be away
from doors or windows.
¢ How to attach the indoor unit
Hook the claws of the bottom frame to
the mounting plate.
¢ How to remove the indoor unit.
Push up the marked area (at the lower
part of the front grille) to release the
claws.
14
Mounting plate
Bind with plastic tape.
Return Air
Air flow
(Indoor)
min. 50
Required space
(Space for
maintenance)
Remove pipe port cover
here for left-bottom piping.
• How to set drain plug
Insert a hexagon wrench (4mm)
Wrap insulating tape around the bent portion of refrigerant pipe.
Overlap at least half the width of the tape with each turn.
Drain hose
Bottom frame
Insert drain hose
to this depth so
it won't be pulled
out of drain pipe.
50 mm or more
Outer wall
min. 50
(Space for
maintenance)
All dimensions are in mm
Bottom frame
Front grille
Remove pipe port cover
here for left-side piping.
Left-side piping
Left-back piping
Left-bottom piping
Do not apply lubricating oil (refrigerant
machine oil) when inserting.
Application of causes deterioration
and drain leakage of the plug.
Mounting plate
Refrigerant pipes
M4 × 12L (2 point)
Inner wall
Drain hose
Vinyl chloride drain pipe
(VP-30)
Mounting plate
Claw
Mark (rear side)