Installation Guideline
5. Wiring
IMPORTANT:
* The figures shown in the table are for information purpose only. They should be checked
and selected to comply with the local/national codes of regulations. This is also subject to
the type of installation and conductors used.
** The appropriate voltage range should be checked with label data on the unit.
Cooling Unit (single phase)
Interconnection
Indoor Unit
cable
Terminal Block
COMP
N1
N
L
There must be an all pole disconnection
in the supply mains with a contact
separation of at least 3mm.
Interconnection
Indoor Unit
cable
Terminal Block
COMP
N1
N
L
Power Supply Cable
Fuse / Circuit
There must be an all pole disconnection
in the supply mains with a contact
separation of at least 3mm.
16
Outdoor Unit
Terminal Block
COMP
N
Power
Fuse /
Main
Supply
Circuit
Switch
Cable
Breaker
L / L1
Power
N / L2
Supply
Outdoor Unit
Terminal Block
COMP
N
Main Switch
N / L2
Power
L / L1
Supply
Breaker
Model
Indoor
Outdoor
Voltage range**
Power supply cable size*
Number of conductors
Interconnection cable size*
Number of conductors
Recommended fuse /circuit breaker rating A
Model
Indoor
Outdoor
Voltage range**
Power supply cable size*
Number of conductors
Interconnection cable size*
Number of conductors
Recommended fuse /circuit breaker rating A
28/35A
50A
60A
28/35A
50A
60A
220-240V/~/50Hz +
mm
1.5
2.5
2.5
2
3
3
3
mm
1.5
2.5
2.5
2
3
3
3
16
20
20
28/35P
50/60P
28/35F
50/60C
220-240V/~/50Hz +
mm
1.5
2.5
2
3
3
mm
1.5
2.5
2
3
3
16
20