Table 28 - Air Shutter Adjustment Guidelines
Amount of Primary Air
If air shutter is
closed too far
If air shutter is
open too far
Table 29 - Main Burner Shutter Opening—Factory Setting
Models
NOTE: When rear venting or running fireplace for an extended period of time the shutter
should be moved to a more open position by pulling rod down. (especially on LP gas)
1. Move the adjustment rod down to increase air flow and up to decrease it. The rod is located in the lower control
compartment. Position the air shutter to the factory setting (Table 29).
2. Light the fireplace. Follow the lighting procedure on the lighting label in the control compartment or Pages 71-74.
3. Allow the burner to operate for at least fifteen (15) minutes while observing the flame continuously to ensure that
the proper flame appearance is achieved (Figure 34). If the following conditions are present, adjust accordingly.
• If flame appears sooty, adjust the air shutter, incrementally, to a more open position until the proper flame
appearance is achieved.
• If flame remains blue, adjust the air shutter, incrementally, to a more closed position until the proper flame
appearance is achieved.
4. When satisfied that the burner flame appearance is normal. Turn fireplace to the off position, and reinstall the
facade, then proceed to finish the installation.
Figure 34 - Burner Flame Appearance
Flame Color
Flame will
be orange
Flame will
be blue
Natural Gas
All
1/4" (6.35 mm)
35" Logs
Air Shutter Adjustment
Air shutter gap should be increased
Air shutter gap should be decreased
Propane Gas
1/2" (12.7 mm)
900948-00C, 06/2019
Figure 33 - Air Shutter Adjustment Rod
Adjustment
Set-Screw
Burner
Tube
Air Shutter
Adjustment
Rod Down
(Fully-Open
Position)
40" / 45" Logs
Installation
Adjustment
Rod Up
(Fully-Closed
Position)