Superior Fireplaces DRT2000-C Series Installation And Operation Instructions Manual page 34

Direct-vent gas fireplaces
Hide thumbs Also See for DRT2000-C Series:
Table of Contents

Advertisement

Innovative Hearth Products
DRT2000-C Series Direct-Vent Gas Fireplaces
Table 23 - Top Vent—One 90° Elbow, Elbow Connection NOT at Fireplace
H Maximum
feet
5
10
15
25
Install the U-shaped vent restrictor in any vent run with more than 4 ft of vertical rise. See
Page 22 for more information.
See Table 20 as an aid in venting component selection for a particular range of exterior wall thicknesses.
If 25 ft of (H) horizontal vent run is needed, then 5 ft minimum of (V) vertical vent will be required.
This table shows a 1 (V) to 5 (H) ratio. For every 1 ft of (V) vertical, you are allowed 5 ft of (H) horizontal
run, up to a maximum horizontal run of 25 ft (7.62 m).
NOTE: The compact termination can be used on 35" models only. All other models require the
small square termination or the horizontal square termination.
Table 24 - Rear Vent—Two 90° Elbows
H + H
Maximum
1
feet
meters
5
1.524
10
3.048
15
4.572
25
7.62
V + H + H
= 60 ft (18.288 m) maximum
1
H = 8 ft (2.438 m) maximum
H + H
= 25 ft (7.62 m) maximum
1
Install the U-shaped vent restrictor in any vent run with more than 4 ft of vertical rise. See
Page 22 for more information.
See Table 20 as an aid in venting component selection for a particular range of exterior wall thicknesses.
If 25 ft of (H) horizontal vent run is needed, then 5 ft minimum of (V) vertical vent will be required.
This table shows a 1 (V) to 5 (H) ratio. For every 1 ft of (V) vertical, you are allowed 5 ft of (H) horizontal
run, up to a maximum horizontal run of 25 ft (7.62 m).
NOTE: The compact termination can be used on 35" models only. All other models require the
small square termination or the horizontal square termination.
Table 25 - Top Vent—Two 90° Elbows
H + H
Maximum
1
feet
3
5
10
15
25
V + H + H
= 60 ft (18.288 m) maximum
1
H + H
= 25 ft (7.62 m) maximum
1
Install the U-shaped vent restrictor in any vent run with more than 4 ft of vertical rise.
See Page 22 for more information.
See Table 20 as an aid in venting component selection for a particular range of exterior wall
thicknesses.
If 25 ft of (H) horizontal vent run is needed, then 5 ft minimum of (V) vertical vent will be
required.
This table shows a 1 (V) to 5 (H) ratio. For every 1 ft of (V) vertical, you are allowed 5 ft of (H)
horizontal run, up to a maximum horizontal run of 25 ft (7.62 m).
NOTE: The compact termination can be used on 35" models only. All other models
require the small square termination or the horizontal square termination.
34
meters
feet
1.524
1
3.048
2
4.572
3
7.62
5
H Maximum
feet
meters
2
0.610
4
1.219
6
1.829
10
3.048
V Minimum
meters
feet
0.91
Elbow only
1.524
1
3.048
2
4.572
3
7.62
5
V Minimum
meters
0.305
0.610
0.914
When using Secure Flex,
use Firestop/Spacer
1.524
SF4.5VF.
When using Secure Flex,
use Firestop/Spacer
SF4.5HF.
V Minimum
feet
meters
1
0.305
2
0.610
3
0.914
5
1.524
meters
0.305
0.610
0.914
1.524
*
When using Secure
Note - When using
Secure Flex
Flex
, use ceiling
®
Firestop/Spacer SF4.5VF.
firestop/spacer
SF4.5VF.
When using Secure Flex,
**
When using Secure
use Firestop/Spacer
SF4.5HF.
Flex, use wall
firestop/spacer
SF4.5HF.
H
H
Min. One
Foot Vent
firestop/
Section
Required
SV4.5VF *
Wall firestop/
Wall Firestop/Spacer
spacer SV4.5HF **
(SV4.5HF)
*
When using Secure Flex
®
Ceiling
ceiling firestop/spacer SF4.5VF.
Firestop/Spacer
(SV4.5VF)
**
When using Secure Flex, use
wall firestop/spacer SF4.5HF.
H1
H 1
Ceiling
firestop/
Ceiling
spacer
Firestop/Spacer
SV4.5VF *
SV4.5VF*
Wall firestop/
Wall Firestop/
spacer
Spacer
SV4.5HF **
SV4.5HF**
V
V
*
When using Secure Flex
*When using Secure Flex , use
ceiling firestop/spacer SF4.5VF.
Ceiling Firestop/Spacer SF4.5VF.
**
When using Secure Flex, use
**When using Secure Flex, use
wall firestop/spacer SF4.5HF.
Wall Firestop/Spacer SF4.5HF.
Wall firestop/spacer
Wall Firestop/Spacer
SV4.5HF **
(SV4.5HF)
H1
H 1
Wall firestop/
Wall
spacer
Firestop/Spacer
, use
TM
SV4.5HF **
(SV4.5HF)
Ceiling firestop/
Ceiling
spacer SV4.5VF *
Firestop/Spacer
(SV4.5VF)
Min. One Foot Vent
Section Required
Installation
900948-00C, 06/2019
V
V
Ceiling
spacer
, use
H
H
, use
®
®
H
H
V
V