Operating Programme - Riello RG1RKD Installation, Use And Maintenance Instructions

Light oil burner
Table of Contents

Advertisement

Available languages

Available languages

6.6

Operating programme

Normal operation
POWER SUPPLY
P
H T
P H
K
t
1
t
2
F M
M
I D
V 1
P
T R
V 2
F
Green
blink
L E D
F
Green
blink
L E D
Signal not requested
Lockout due to ignition failure
POWER SUPPLY
P
H T
P H
K
t
1
t
2
F M
M
I D
V 1
P
T R
V 2
F
Green
blink
L E D
Start-up, calibration and operation of the burner
20137242
t
3
t
4 i
t
t
t
3 i
s
5 i
t
5
Green blink
Orange
Green
blink
No flame during operation
t
4 l
Lockout
Green blink
Orange
blink
Green
20137244
t
3
t
4 i
t
t
t
3 i
s
5 i
Lockout
t
5
Green blink
Orange
Red
blink
Fig. 22
Lockout due to extraneous light during pre-purging
POWER SUPPLY
P
H T
P H
K
F M
M
I D
V 1
P
T R
V 2
F
L E D
Key
Fig. 21
F
– Flame sensor
FM – Fan motor
HT – Heat request
ID
– Ignition device
Thermostat enabling start-up after
K
pre-heating
LED – LED colour inside the button
Oil heater
PH –
t1
– Standby time
t2
– Initialisation time for checking
t3
– Pre-purging time
t3l
– Checks for presence of extraneous light during pre-purg-
ing phase
t4i
– Total ignition time
t4l
– Reaction time to achieve safety lockout due to lack of
failure
TR – Adjustment time
ts
– Safety time
V1 – 1st stage valve
V2 – Valve 2nd stage
25
GB
t
1
t
2
t
l
3
Orange blink
Green
Red, green blink
blink
20137245
t
s
Lockout
Red blink
Fig. 23