Mitsubishi Electric SUZ-KA24NAHZ Service Manual page 71

Hide thumbs Also See for SUZ-KA24NAHZ:
Table of Contents

Advertisement

SW2 setting
LEV-C opening pulse on error occurring
0 to 480
ON
1
2 3 4 5 6
Indoor room temperature (TH1) on error
occurring
46 to 102
ON
1
2 3 4 5 6
Indoor pipe temperature / Liquid (TH2)
on error occurring
−38 to 190
ON
1
2 3 4 5 6
Indoor pipe temperature/Cond./Eva.
(TH5) on error occurring
−38 to 190
ON
1
2 3 4 5 6
Outdoor pipe temperature / 2-phase
(TH6) on error occurring
−38 to 190
ON
1
2 3 4 5 6
Outdoor ambient temperature (TH7) on
error occurring
−38 to 190
ON
1
2 3 4 5 6
Outdoor heatsink temperature (TH8) on
error occurring
−40 to 392
ON
1
2 3 4 5 6
OCH754A
Display detail
71
The black square (■) indicates a switch position.
Explanation for display
0 to 480
(When it is 100 pulse or more, hundreds digit, tens
digit and ones digit are displayed by turns.)
Example: When 130 pulse;
0.5 s
46 to 102 [8 to 39°C]
−38 to 190 [−39 to 88°C]
(When the temperature is 32˚F [0°C] or less, "–" and
temperature are displayed by turns.)
Example: When −15˚F;
0.5 s
−38 to 190 [−39 to 88°C]
(When the temperature is 32˚F [0°C] or less, "–" and
temperature are displayed by turns.)
Example: When −15˚F;
0.5 s
−38 to 190 [−39 to 88°C]
(When the temperature is 32˚F [0°C] or less, "–" and
temperature are displayed by turns.)
Example: When −15˚F;
0.5 s
−38 to 190 [−39 to 88°C]
(When the temperature is 32˚F [0°C] or less, "–" and
temperature are displayed by turns.)
Example: When - 15˚F;
0.5 s
−40 to 392 [−40 to 200°C]
(When the temperature is 32˚F [0°C] or less, "–" and
temperature are displayed by turns.)
(When the temperature is 100˚F or more, hundreds
digit, tens digit and ones digit are displayed by
turns.)
0.5 s
2 s
1
30
0.5 s
2 s
15
0.5 s
2 s
15
0.5 s
2 s
15
0.5 s
2 s
15
Unit
Pulse
˚F [°C]
˚F [°C]
˚F [°C]
˚F [°C]
˚F [°C]
˚F [°C]