Mitsubishi Electric Mr.Slim SUZ-KA25VA5 Installation Manual

Mitsubishi Electric Mr.Slim SUZ-KA25VA5 Installation Manual

Hide thumbs Also See for Mr.Slim SUZ-KA25VA5:

Advertisement

Air-Conditioners
SUZ-KA25, KA35, KA50, KA60, KA71VA5

INSTALLATION MANUAL

For safe and correct use, read this manual and the indoor unit installation manual thoroughly before installing
the air-conditioner unit.
INSTALLATIONSHANDBUCH
Aus Sicherheitsgründen und zur richtigen Verwendung vor der Installation die vorliegende Bedienungsanleitung
und die Installationsanleitung der Innenanlage gründlich durchlesen die Klimaanlage.
MANUEL D'INSTALLATION
Avant d'installer le climatiseur, lire attentivement ce manuel, ainsi que le manuel d'installation de l'appareil
intérieur pour une utilisation sûre et correcte.
INSTALLATIEHANDLEIDING
Lees deze handleiding en de installatiehandleiding van het binnenapparaat zorgvuldig door voordat u met het
installeren van de airconditioner begint.
MANUAL DE INSTALACIÓN
Para un uso correcto y seguro, lea detalladamente este manual y el manual de instalación de la unidad interior
antes de instalar la unidad de aire acondicionado.
MANUALE DI INSTALLAZIONE
Per un uso sicuro e corretto, leggere attentamente il presente manuale ed il manuale d'installazione dell'unità
interna prima di installare il condizionatore d'aria.
EΓΧEIPIΔIO OΔHΓIΩN EΓKATAΣTAΣHΣ
Για σωστή και ασφαλή χρήση, διαβάστε προσεκτικά αυτό το εγχειρίδιο καθώς και το εγχειρίδιο εγκατάστασης
της εσωτερικής μονάδας, προτού εγκαταστήσετε τη μονάδα του κλιματιστικού.
MANUAL DE INSTALAÇÃO
Para uma utilização segura e correcta, leia atentamente este manual e o manual de instalação da unidade
interior antes de instalar o aparelho de ar condicionado.
INSTALLATIONSMANUAL
Læs af sikkerhedshensyn denne manual samt manualen til installation af indendørsenheden grundigt, før du
installerer klimaanlægget.
INSTALLATIONSMANUAL
Läs bruksanvisningen och inomhusenhetens installationshandbok noga innan luftkonditioneringen installeras
så att den används på ett säkert och korrekt sätt.
MONTAJ ELKİTABI
Emniyetli ve doğru kullanım için, klima cihazını monte etmeden önce bu kılavuzu ve iç ünite montaj kılavuzunu
tamamıyla okuyun.
FOR INSTALLER
FÜR INSTALLATEURE
POUR L'INSTALLATEUR
VOOR DE INSTALLATEUR
PARA EL INSTALADOR
PER L'INSTALLATORE
ΓΙΑ ΑΥΤΟΝ ΠΟΥ ΚΑΝΕΙ ΤΗΝ ΕΓΚΑΤΑΣΤΑΣΗ
PARA O INSTALADOR
TIL INSTALLATØREN
FÖR INSTALLATÖREN
MONTÖR İÇİN
English
Deutsch
Français
Nederlands
Español
Italiano
Eλληνικά
Português
Dansk
Svenska
Türkçe

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric Mr.Slim SUZ-KA25VA5

  • Page 1: Installation Manual

    Air-Conditioners SUZ-KA25, KA35, KA50, KA60, KA71VA5 INSTALLATION MANUAL FOR INSTALLER English For safe and correct use, read this manual and the indoor unit installation manual thoroughly before installing the air-conditioner unit. INSTALLATIONSHANDBUCH FÜR INSTALLATEURE Deutsch Aus Sicherheitsgründen und zur richtigen Verwendung vor der Installation die vorliegende Bedienungsanleitung und die Installationsanleitung der Innenanlage gründlich durchlesen die Klimaanlage.
  • Page 2: Table Of Contents

    Contents 1. The following should always be observed for safety ..... . 2 6. Electrical work ........... 6 2.
  • Page 3: Installation Diagram

    3. Installation diagram ■ 3.1. Outdoor unit (Fig. 3-1) SUZ-KA25VA5 SUZ-KA35VA5 Ventilation and service space ■ SUZ-KA25VA5 SUZ-KA35VA5 A 100 mm or more B 350 mm or more C Basically open 100 mm or more without any obstruction in front and on both sides of the unit.
  • Page 4: Refrigerant Piping Work

    5. Refrigerant piping work 5.1. Refrigerant pipe (Fig. 5-1) ► Check that the difference between the heights of the indoor and outdoor units, the length of refrigerant pipe, and the number of bends in the pipe are within the limits shown below. Indoor unit (A) Pipe length (B) Height...
  • Page 5: Warning

    5. Refrigerant piping work 5.2.5. Check (Fig. 5-7) • Compare the flared work with a figure in right side hand. • If flare is noted to be defective, cut off the flared section and do flaring work again. Scratch on flared plane Smooth all around Inside is shining without any scratches Cracked...
  • Page 6: Electrical Work

    6. Electrical work 6.1. Outdoor unit (Fig. 6-1, Fig. 6-2, Fig. 6-3, Fig. 6-4) Remove the service panel. Wire the cables referring to the Fig. 6-1, Fig. 6-2, Fig. 6-3 and the Fig. 6-4. ■ ■ SUZ-KA25/35/50VA5 SUZ-KA60/71VA5 1 S 2 S Indoor unit Outdoor unit Indoor unit...
  • Page 7: Maintenance

    6. Electrical work 6.2. Field electrical wiring Outdoor unit model SUZ-KA35 *3 SUZ-KA25/KA35 SUZ-KA50/KA60/KA71 Outdoor unit power supply ~/N (single), 50 Hz, 230 V ~/N (single), 50 Hz, 230 V ~/N (single), 50 Hz, 230 V Outdoor unit input capacity Main switch (Breaker) 10 A 16 A 20 A...
  • Page 8: Pumping Down

    8. Pumping down When relocating or disposing of the air conditioner, pump down the system following the procedure below so that no refrigerant is released into the atmosphere. 1 Turn off the power supply (circuit breaker). 7 Turn off the power supply (circuit breaker), remove the gauge manifold valve, and 2 Connect the gauge manifold valve to the service port of the stop valve on the gas then disconnect the refrigerant pipes.
  • Page 9 EU-OVERENSSTEMMELSESERKLÆRING CE-ERKLÆRING OM SAMSVAR MITSUBISHI ELECTRIC CONSUMER PRODUCTS (THAILAND) CO., LTD. AMATA NAKORN INDUSTRIAL ESTATE 700/406 MOO 7, TAMBON DON HUA ROH, AMPHUR MUANG, CHONBURI 20000, THAILAND hereby declares under its sole responsibility that the air conditioners and heat pumps described below for use in residential, commercial and light-industrial environments: erklärt hiermit auf seine alleinige Verantwortung, dass die Klimaanlagen und Wärmepumpen für das häusliche, kommerzielle und leicht-industrielle Umfeld wie unten beschrieben:...
  • Page 10 <ENGLISH> <ΕΛΛΗΝΙΚΑ> English is original. The other languages versions are translation of the original. Η γλώσσα του πρωτοτύπου είναι η αγγλική. Οι εκδόσεις άλλων γλωσσών είναι μεταφράσεις του πρωτοτύπου. CAUTION ΠΡΟΣΟΧΗ • Refrigerant leakage may cause suffocation. Provide ventilation in accordance with EN378-1. •...
  • Page 11 Please be sure to put the contact address/telephone number on this manual before handing it to the customer. HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN Authorized representative in EU: MITSUBISHI ELECTRIC EUROPE B.V. RG79Y757H01 Printed in Thailand...

Table of Contents