Dimplex BPH100M Instruction Manual page 19

Bathroom panel heater
Table of Contents

Advertisement

Boost Settings
Default Boost Target Temperature
This is the default Boost Target Temperature that is used when 'Boost Mode' is activated.
Max. Boost Duration
This is the maximum length of time that the user is able to activate 'Boost' for.
Shown in minutes (when under an hour) or hours (if over an hour) in the following increments: 30 min, 1 hour, 2
hours, 3 hours, 4 hours.
The value chosen will be the max allowed when boost is activated.
Setback Settings
Setback is a function that only modifi es Timer Mode operation. When Setback is enabled it overrides any Heating
O
period to maintain a constant temperature.
This can be used to prevent the room temperature from falling below a minimum value while there is no demand
for heat (Heating On).
The value of this temperature is restricted to a value between 7 and 18 °C. This is because Setback should not be
treated as a regular Heating On period.
Date & Time Settings
This allows the Time, Date and Daylight Savings Time settings to be modifi ed.
Sound
Audio feedback when the user presses a button can be enabled or disabled here.
'Comms' (Communications)
This allows Wireless Connectivity features to be enabled or disabled.
Entering this menu item will display a list of available communications methods
to that heater.
Adaptive
Open Window Detection
This is a global setting that can interrupt any active mode. Activating this setting enables Open Window Detection
to switch the Heater to a Heating O
NOTE:
In environments where the product may read sudden decreases in temperature, this feature may
activate in error. This can occur in drafty or poorly insulated environments as well as if the heater is
undersized for the room. This feature should be disabled using the instructions above if activating for
reasons other than the intended purpose. If you think that your environment is not as described here
and this feature is activating, please contact our customer care team with the details on the rear page
of this document.
state if it detects an open window in the room it's operating in.
19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bph100g

Table of Contents