Make-Up Air Damper Relay Switch (Optional) - Thermador HPIN42WS Installation Instructions Manual

Island hoods
Hide thumbs Also See for HPIN42WS:
Table of Contents

Advertisement

Available languages

Available languages

Make-Up Air Damper Relay
Switch (optional)
Local codes may require the use of an additional backdraft
and/or make-up air damper. Contact your local HVAC
professional for specific requirements.
This hood provides a relay switch to connect a Make-Up
Air Damper (120V max). Installations will vary according to
the location in the home where the unit is installed and the
damper used. Use the following illustration as guidance
for your installation. Always comply with local code
requirements.
1. Access the hood's wiring.
2. Route the Make-up Air Damper harness through the
strain relief to the terminal block.
The Make-up air kit hot and return connections
can use either terminal connection. There is no
polarity requirement for the two pin terminal
block.
3. Secure the ground wire with the green T-20 ground
screw.
Page. 18