Thermador HPIN42WS Installation Instructions Manual page 16

Island hoods
Hide thumbs Also See for HPIN42WS:
Table of Contents

Advertisement

Available languages

Available languages

3. Route the blower motor's plug connector through the
Heyco.
4. Route the blower harness through the self-locking
clip.
5. Connect the blower's harness to the hood harness.
Page. 16
Installing a Remote Blower or In-line
Blower
For complete installation instructions see the instructions
supplied with the blower unit.
Remote Blower
Depending on preference and ducting situation, these
blowers can be mounted on the roof or exterior wall of the
home. An exterior installation may be more appealing to
reduce noise in the kitchen.
inches (mm)
2⅛"
(54)
1⅞"
(48)
6½"
(165)
12⅞"
(327)
In-line Blower
To minimize noise in the kitchen, these blowers are
mounted along the duct line anywhere between the
kitchen and the exterior wall. If there is easy access to duct
line (in an attic, for example), this may be an appealing
option.
inches (mm)
12⅛"
(308)
ø
9⅞"
(251)
13⅝"
(346)
1¾"
(45)
12⅛"
(308)
dia.9⅞"
(251)
20¾"
(527)
10"
(254)
19"
(485)
12"
(305)
⅞" (22)
19⅛"
(486)
1¾"
(44)
12⅞"
(327)
14⅜"