SAFETY & STANDARD FEATURES
2
1 & 2
4
3
6
Safe-T-Beam® (STB) Non-Contact
Reversing System
Puts an invisible beam across the door opening. The
door stops and reverses to the full open position if
anything passes through the beam. LED indicator
lights on the powerhead and on the STBs provide
self-diagnostics if an operational problems exists.
Door Detect™ Monitoring System
Monitors the Safe-T-Beam® system to ensure proper
functionality and will automatically stop and
reverse a closing door if a problem is detected.
Safe-T-Reverse® Contact Reversing System
Automatically stops and reverses a closing door
within two seconds of contact with an object.
Manual Emergency Release
Manually releases door from door opener. Used during a power failure or other emergency to allow manual opening and closing of door.
DO NOT use emergency release cord to pull door
®
SmartSet
Electronic Programming
Easily adjust the programming to set limits and program new remotes.
Automatic Lighting System
Single or Dual Bulb lighting system supplies light for safer evening exits and entries. Turn ON when door is activated and automatically
turns OFF 4 minutes later.
Intellicode®
An encryption system that enhances the security of the door opener by continuously changing the access code
each time the remote is used. The door opener responds to each new code only once. An access code copied from
a working system and tried again, will not control the door opener.
Wall Console (With select models)
Operates door opener from inside garage. The wall console has an indicator light with:
Open/Close, Sure-lock™, and independent light control buttons.
1.) Indicator Light
Large white button will display Red when wall console is properly wired and Sure-Lock™ is OFF. When Sure-Lock™
is ON, this light is o .
2.) Open/Close Button
Use this button to open or close garage door. When Sure-Lock™ is ON the Open/Close button will CLOSE the door
only.
NOTE: Constant button pressure in the CLOSE mode will override STB fault in the powerhead and close door.
3.) Independent Light Control Button
Use this button to turn the powerhead lights ON. Powerhead lighting will remain ON until this button is pressed
again or a door action has been completed.
4.) Sure-Lock™ Button
When Sure-Lock™ is ON, and the door is closed, the powerhead cannot be activated by the wall console or a
remote.
• Slide switch up to activate Sure-Lock™ (red light goes o ).
• Slide switch down to turn Sure-Lock™ OFF (red light goes on).
Home Link® and Car2U® compatible. See instructions in this manual, refer to the motor vehicle manual or visit
www.geniecompany.com for instructions.
Factory Programmed Remote Control
For ease and speed of installation, the remote included with this opener comes from the factory, pre-programmed.
No additional steps are required to activate the door using the remote.
Genie Battery Backup (BBU)
Available on some models. Provides power to opener in the event of a power failure.
NOTE: Genie Battery Backup will only operate after opener installation is completed and Travel Limits have been
set.
DO NOT INSTALL BATTERY BACKUP UNTIL OPENER IS FULLY INSTALLED AND PROGRAMMED
Safe-T-Beam® (STB) FUNCTION
1. The Safe-T-Beam® has no e ect on the door during an opening cycle.
2. If the Safe-T-Beam® detects an obstruction when trying to close the
door, it will not allow the door to close.
3. When the garage door is closing, if Safe-T- Beam® is interrupted by
a person or obstacle, the garage door will stop its downward travel
and reverse automatically to its fully opened position.
4. If the Safe-T-Beam® System fails, loses power, or is installed
improperly, press and hold the wall console "open/close" button
until the door reaches its fully closed position. If you release
the "open/close" button on the wall console during the closing
movement, the door will reverse automatically to its fully-opened
position.