EdgeStar AP12000S-1 Owner's Manual
Hide thumbs Also See for AP12000S-1:

Advertisement

Portable Air Conditioner
AP12000S-1
Owner's Manual
For more information on other great EdgeStar products on the web, go to http://www.edgestar.com

Advertisement

Table of Contents
loading

Summary of Contents for EdgeStar AP12000S-1

  • Page 1 Portable Air Conditioner AP12000S-1 Owner’s Manual For more information on other great EdgeStar products on the web, go to http://www.edgestar.com...
  • Page 2: Important Safety Information

    2. Press the TEST button on the LCDI plug. This should trip the plug and cut the power to the air conditioner. If the plug does not trip and you are able to turn on the unit, please contact EdgeStar support.
  • Page 3: Table Of Contents

    ENERGY SAVING GUIDE ................... 14 MAINTENANCE ....................15 ................... 15 LEANING THE UNIT ................. 15 LEANING THE PRE FILTER ................15 REPARATION FOR TORAGE TROUBLESHOOTING ..................16 ................. 17 ROUBLESHOOTING CONTINUED SPECIFICATIONS ....................18 EDGESTAR LIMITED WARRANTY ..............19 EdgeStar Portable Air Conditioner...
  • Page 4: Introduction

    Introduction Thank you for purchasing this EdgeStar portable air conditioner. We are glad you chose us. We believe that your purchase of this product opens a relationship between you and EdgeStar. We will provide the customer support needed to nurture that relationship.
  • Page 5: Parts Identification

    Control Panel Front View Front Air Vent Handle Caster Pre-filter Back View Air Intake Exhaust Outlet Power Cord CAUTION: Make sure the drain plug is firmly installed before using the unit. This will prevent leaking. Drain Valve EdgeStar Portable Air Conditioner...
  • Page 6: Installing The Carbon Filter

    Installing the Carbon Filter Your portable air conditioner ships with a pre-filter and an activated carbon filter. The carbon filter will help remove contaminates and odors from the air. It is recommended you replace the carbon filter every two to three months, or as needed. It is necessary to clean the pre-filter periodically.
  • Page 7: Window Kit Installation Instructions

    Your window kit can be installed on a horizontal or vertical sliding window as shown in the following pictures: Follow the instructions on the next pages to install the window kit. EdgeStar Portable Air Conditioner...
  • Page 8: Installing The Grated Adapter

    Installing the grated adapter  1. Insert the round grated adapter through the back grooved side of the window kit plate with hole.  2. Secure the grated adapter by fastening the screws from flat side of the window kit plate to the holes on the grated adapter.
  • Page 9: Installing The Window Plates

    4. Lower the window to secure the window kit in place. You CAUTION: Secure your may need to use duct tape to better secure the window kit. window by using window locks. Please contact your dealer to purchase window locks. EdgeStar Portable Air Conditioner...
  • Page 10: Attaching The Duct Connectors To The Exhaust Hose

    Attaching the duct connectors to the exhaust hose  5. Attach the connectors to the hose: A. Extend the ends of the exhaust hose B. Thread the duct connector on by turning it clockwise until it stops.  6. Roll the unit towards the window kit. Leave a space that is at least 20 inches to the wall.
  • Page 11: Connecting The Duct Connector To The Unit

    8. Align the slots on the duct connector to the tabs on the grated adapter and snap in place. After you have installed the exhaust hose and window kit, you can plug in your portable air conditioner and start using it. EdgeStar Portable Air Conditioner...
  • Page 12: Draining The Unit

    Your portable air conditioner is designed to exhaust condensate Notes about the Exhaust water that is collected from the air. This water, in either gaseous or hose droplet form, will be expelled out the exhaust port of the unit. Please take this into account when deciding how to vent it. 1.
  • Page 13: Control Panel Overview

    Use the Up and Down buttons to set the number of hours. LCD Display The LCD can display the ambient temperature, set temperature, and the number of hours when setting the timer. Infrared Receiver for the remote control. Sensor EdgeStar Portable Air Conditioner...
  • Page 14: Operating The Control Panel

    Operating the Control Panel Use the Power button to turn the portable air conditioner on and off. Power By default when you first use the power button, the unit will begin to operate in cooling mode. The unit will remember the last used mode/settings if you shut down and restart.
  • Page 15: Fan Only Mode

    In high humidity situations, the internal water reservoir may fill. The Water Light unit will automatically shut off and the water light will turn on. Once the water is manually drained, the unit will operate normally. EdgeStar Portable Air Conditioner...
  • Page 16: Using The Remote Control

    Using the Remote Control The remote control can be used instead of the control panel to remotely operate your portable air conditioner. The functions on the remote are the same as on the control panel. Power Button Mode Button Speed Button Up and Down Buttons Timer Button...
  • Page 17: Energy Saving Guide

     To prolong the compressor's life, please wait at least 3 minutes before turning the unit back on after shutting it off.  Inspect and keep the pre-filters clean by cleaning regularly.  Inspect and replace the activated carbon filters regularly.  Perform routine maintenance. EdgeStar Portable Air Conditioner...
  • Page 18: Maintenance

    2-3 months or as needed. Contact Clean the pre-filter periodically. If the unit is used in a dusty EdgeStar retailers for environment you may need to clean it on a weekly basis. replacement filters. Warning: Never operate the unit without the pre-filter.
  • Page 19: Troubleshooting

    The control panel Unit may have a faulty Contact customer lights blink randomly control panel service EdgeStar Portable Air Conditioner...
  • Page 20: Troubleshooting Continued

    Troubleshooting continued Issue Possible Cause Solution My air conditioner is Unit is not operating in Set the unit to be in not cooling at all cooling mode cooling mode, and lower the set temperature (pg. 11) The compressor is not The compressor may take up to 3 minutes to turn on, or longer if it is...
  • Page 21: Specifications

    Description of product Portable Air Conditioner Model AP12000S-1 Voltage/Frequency AC 115V~60Hz Input Power 1200W Current 10.8A Color Silver Dehumidifying capacity 90 Pints/Day Coolant R410-A Timer 24 Hour Dimensions 17 1/10” x 30 9/10” x15” WxHxD Weight 68 lbs EdgeStar Portable Air Conditioner...
  • Page 22: Edgestar Limited Warranty

    EdgeStar authorized repair facility. PARTS: For a period of ONE (1) YEAR from the date of original purchase, EdgeStar will supply new, rebuilt, or refurbished parts free of charge. EdgeStar may request a defective part be returned in exchange for the replacement part.
  • Page 23 Register your product, download owner’s manuals, access additional troubleshooting resources, and obtain more information on other great EdgeStar products on the web at: http://www.edgestar.com Product contents and specifications may change without notice. Copyright © 2010 Living Direct, Inc. All rights reserved.

Table of Contents