Gas Conversion; Warnings; Procedures - Biasi GARDA PLUS HE M110B.24SM/E User Manual And Installation Instructions

Table of Contents

Advertisement

8

GAS CONVERSION

8.1

Warnings

The commissioning of this boiler and
system must only be undertaken by a
professionally qualified person in ac-
cordance with the requirements of the
Gas Safe Installation and Use Regula-
tions and be approved by Gas Safe.
Components used to adapt it to the type
of gas available must be genuine parts
only.
Factory setting = Natural gas
8.2

Procedures

Check that the gas cock (13 in
Fig. 8.1) fitted under the boiler is
turned off and the appliance is
switched off at the mains isolat-
ing spur.
13
Closed position
Fig. 8.1
• Remove the front panel of the case (see
the section "Dismantling the external pan-
els" to page 55) and lower the control pan-
el (see section "Electrical connections" to
page 42).
• Take off the lid of the sealed chamber.
• Unscrew the connector A (Fig. 8.2), re-
move the fixing fork B and remove the pipe
- 52 -
GAS CONVERSION
Fig. 8.2
Fig. 8.3
• Carry out the conversion for the type of
C (Fig. 8.3).
A
C
gas, replacing the restrictors gas correctly
(Fig. 8.4).
B