Electrical Data
Voltage
Frequency
Power consumption
Protection degree
External fuse rating
Internal fuse rating
Flue design
Coaxial flue pipe diameter
Twin split pipes diameter
Roofl flue pipe diameter
Nominal heat flow rate
(A) (E)
Exhaust temperature
(E)
Smoke production
(E)
CO
contents
2
CO
content with gas G20
2
(range min-max)
CO
content with gas G31
2
(range min-max)
At nominal heat input of 25,7 kW
CO
content with gas G20
2
(range min-max)
CO
content with gas G31
2
(range min-max)
At minimum heat input of 6,0 kW
Other flue gas figures
At nominal heat input - non condensing
O
content
2
CO content
Exhaust temperature
(D)
TECHNICAL INFORMATION
V
230
Hz
50
W
108
IPX4D
A
3
N°2-
3,15 AF
A
N°1-0,4 T
mm
60/100
mm
80/80
mm
80/125
kW
25,7
°C
85
kg/h
40
%
9,0-9,8
%
10,0-11,0
(A)(E)
%
9,0-9,8
%
10,0-11,0
(A)(E)
%
4,3-4,3
ppm
200
°C
85
Other specifications
Height
Width
Depth
Weight (dry)
Water volume in the boiler
(up to 1 bar)
Referred to the net calorific value at 15 °C and
(A)
1013,25 mbar:
G20 = 34,02 MJ/m
- G31 = 46,34 MJ/kg
3
Referred to the gross calorific value at 15 °C and
(B)
1013,25 mbar:
G20 = 37,78 MJ/m
- G31 = 50,37 MJ/kg
3
The value is used in the UK Government's Standard
(C)
Assessment Procedure (SAP) for energy rating of
dwellings. The test data from which it has been calcu-
lated have been certified by a notified body.
Values subject to tolerance.
(D)
Values refer to tests with a 1 m flue working at the
(E)
nominal heat input.
mm
803
mm
400
mm
350
kg
44,5
l (kg)
2