Fig. 6.15
• Connect the room thermostat between ter-
minals 1 and 3 as shown in Fig. 6.16 or
Fig. 6.17.
Do not connect live wires to ter-
minals to which the room ther-
mostat must be connected.
T
Room thermostat
(230V rating)
L
3
2
1
Fig. 6.16
INSTALLATION
N
Power supply
terminal block
External controls
terminal block
Room thermostat
T
with delay resistor
(230V rating)
L
3
2
1
Fig. 6.17
• Route the electrical supply flexible cord
and the external control flexible cord as
illustrated in Fig. 6.18. Lock the flexible
cords in place with the flexible cord clamps
To the external
control device
Fig. 6.18
It is not necessary to cut away the plas-
tic service panel to route the electrical
cords.
N
Power supply
terminal block
External controls
terminal block
To the fused
spur isolation
switch
- 43 -