When analog special adapters are connected, operations and functions are assigned to the devices shown in
the table below in accordance with the number of connected analog special adapters.
Devices which cannot be written are shaded in the "Operation and function" column in the table below.
1. Special auxiliary relays (M8260 to M8299)
• FX
/FX
3U
3UC
Number
1st analog special adapter
M 8260
Ch1: Input mode switching
M 8261
Ch2: Input mode switching
M 8262
Ch3: Input mode switching
M 8263
Ch4: Input mode switching
M 8264
Not used (disabled)
M 8265
Not used (disabled)
M 8266
Not used (disabled)
M 8267
Not used (disabled)
M 8268
Not used (disabled)
M 8269
Not used (disabled)
2nd analog special adapter
M 8270
Ch1: Input mode switching
M 8271
Ch2: Input mode switching
M 8272
Ch3: Input mode switching
M 8273
Ch4: Input mode switching
M 8274
Not used (disabled)
M 8275
Not used (disabled)
M 8276
Not used (disabled)
M 8277
Not used (disabled)
M 8278
Not used (disabled)
M 8279
Not used (disabled)
3rd analog special adapter
M 8280
Ch1: Input mode switching
M 8281
Ch2: Input mode switching
M 8282
Ch3: Input mode switching
M 8283
Ch4: Input mode switching
M 8284
Not used (disabled)
M 8285
Not used (disabled)
M 8286
Not used (disabled)
M 8287
Not used (disabled)
M 8288
Not used (disabled)
M 8289
Not used (disabled)
4th analog special adapter
M 8290
Ch1: Input mode switching
M 8291
Ch2: Input mode switching
M 8292
Ch3: Input mode switching
M 8293
Ch4: Input mode switching
M 8294
Not used (disabled)
M 8295
Not used (disabled)
M 8296
Not used (disabled)
M 8297
Not used (disabled)
M 8298
Not used (disabled)
M 8299
Not used (disabled)
*1.
In the case of FX
*2.
In the case of FX
236
/FX
/FX
PLCs)
3GC
3U
3UC
PLCs
*1
FX
-4AD-ADP
3U
Ch1: Output mode switching
Ch2: Output mode switching
Ch3: Output mode switching
Ch4: Output mode switching
Ch1: Output hold mode reset Not used
Ch2: Output hold mode reset Not used
Ch3: Output hold mode reset Output hold mode cancel
Ch4: Output hold mode reset Sets whether or not input channel 1 is used.
Not used (disabled)
Not used (disabled)
Ch1: Output mode switching
Ch2: Output mode switching
Ch3: Output mode switching
Ch4: Output mode switching
Ch1: Output hold mode reset Not used
Ch2: Output hold mode reset Not used
Ch3: Output hold mode reset Output hold mode cancel
Ch4: Output hold mode reset Sets whether or not input channel 1 is used.
Not used (disabled)
Not used (disabled)
Ch1: Output mode switching
Ch2: Output mode switching
Ch3: Output mode switching
Ch4: Output mode switching
Ch1: Output hold mode reset Not used
Ch2: Output hold mode reset Not used
Ch3: Output hold mode reset Output hold mode cancel
Ch4: Output hold mode reset Sets whether or not input channel 1 is used.
Not used (disabled)
Not used (disabled)
Ch1: Output mode switching
Ch2: Output mode switching
Ch3: Output mode switching
Ch4: Output mode switching
Ch1: Output hold mode reset Not used
Ch2: Output hold mode reset Not used
Ch3: Output hold mode reset Output hold mode cancel
Ch4: Output hold mode reset Sets whether or not input channel 1 is used.
Not used (disabled)
Not used (disabled)
PLC, versions 1.20 or later are applicable.
3UC
and FX
PLCs, versions 2.61 or later are applicable.
3U
3UC
4 Operations of Special Devices (M8000 and later, D8000 and later)
4.2 Supplement of Special Devices (M8000 and later and D8000 and later)
→ For details, refer to the Analog Control Edition.
Operation and function
*1
FX
-4DA-ADP
3U
Input mode switching Ch1
Input mode switching Ch2
Output mode switching
Not used
Sets whether or not input channel 2 is used.
Sets whether or not output channel is used.
Input mode switching Ch1
Input mode switching Ch2
Output mode switching
Not used
Sets whether or not input channel 2 is used.
Sets whether or not output channel is used.
Input mode switching Ch1
Input mode switching Ch2
Output mode switching
Not used
Sets whether or not input channel 2 is used.
Sets whether or not output channel is used.
Input mode switching Ch1
Input mode switching Ch2
Output mode switching
Not used
Sets whether or not input channel 2 is used.
Sets whether or not output channel is used.