Bryant 580D Product Information Manual page 34

Commercial single package rooftop gas heating/electric cooling units 3 to 25 tons
Table of Contents

Advertisement

FAN PERFORMANCE — 580D036-150 VERTICAL DISCHARGE UNITS (cont)
580D072 (6 TONS)*
Airflow
0.1
(Cfm)
Rpm
Bhp
Watts
1800
942
0.70
646
1900
982
0.80
739
2000
1022
0.91
835
2100
1063
0.99
916
2200
1104
1.13
1039
2300
1130
1.26
1156
2400
1174
1.37
1258
2500
1201
1.48
1361
2600
1246
1.62
1491
2700
1285
1.75
1613
2800
1304
1.87
1726
2900
1345
2.07
1910
3000
1378
2.26
2084
580D072 (6 TONS)* (cont)
External Static Pressure (in. wg)
Airflow
1.2
(Cfm)
Rpm
Bhp
Watts
1800
1395
1.46
1301
1900
1430
1.58
1404
2000
1459
1.67
1482
2100
1489
1.80
1595
2200
1528
1.95
1726
2300
1561
2.13
1884
2400
1584
2.28
2015
2500
1633
2.53
2232
2600
1675
2.77
2436
2700
2800
2900
3000
LEGEND
Bhp
— Brake Horsepower Input to Fan
FIOP
— Factory-Installed Option
Watts — Input Watts to Motor
*Motor drive range is 1070 to 1460 rpm. All other rpms require a field-
supplied drive.
NOTES:
1. Boldface indicates field-supplied motor and drive are required.
2. Values include losses for filters, unit casing, and wet coils. See
page 52 for accessory/FIOP static pressure information.
PERFORMANCE DATA (cont)
External Static Pressure (in. wg)
0.2
Rpm
Bhp
Watts
Rpm
978
0.66
700
1063
1023
0.78
779
1097
1068
0.90
867
1132
1115
1.00
998
1180
1159
1.15
1081
1214
1202
1.29
1140
1248
1237
1.41
1224
1292
1272
1.53
1335
1335
1320
1.68
1482
1368
1361
1.82
1595
1400
1402
1.95
1639
1439
1446
2.16
1814
1477
1489
2.36
2032
1529
1.4
Rpm
Bhp
Watts
Rpm
Bhp
1475
1.56
1387
1542
1.71
1504
1.69
1499
1556
1.82
1532
1.82
1613
1588
1.97
1567
1.99
1761
1626
2.16
1603
2.17
1919
1666
2.37
1637
2.35
2076
1710
2.54
1671
2.55
2249
1756
2.70
1698
2.72
2405
0.4
0.6
Bhp
Watts
Rpm
Bhp
Watts
0.82
771
1147
0.97
0.91
843
1175
1.11
1006
1.01
924
1218
1.23
1106
1.17
1056
1261
1.35
1207
1.28
1148
1310
1.52
1353
1.38
1233
1358
1.69
1499
1.55
1378
1392
1.81
1604
1.71
1517
1427
1.94
1718
1.81
1604
1458
2.06
1823
1.91
1691
1490
2.19
1936
2.08
1840
1543
2.43
2145
2.16
1989
1585
2.65
2335
2.52
2223
1598
2.73
2444
1.6
Watts
1517
1613
1744
1910
2093
2272
2467
3. Maximum continuous bhp is 2.40 and the maximum continuous
watts are 2120. Extensive motor and electrical testing on these units
ensures that the full range of the motor can be utilized with confi-
dence. Using your fan motors up to the wattage ratings shown will
not result in nuisance tripping or premature motor failure. Unit war-
ranty will not be affected. See Evaporator-Fan Motor Performance
table on page 55 for additional information.
4. Use of a field-supplied motor may affect wire sizing. Contact your
local representative for details.
5. Interpolation is permissible. Do not extrapolate.
34
0.8
Rpm
Bhp
Watts
Rpm
891
1248
1.20
1081
1322
1266
1.29
1156
1356
1303
1.41
1258
1397
1340
1.53
1361
1428
1375
1.63
1447
1459
1410
1.72
1526
1488
1460
1.90
1683
1532
1518
2.16
1910
1575
1562
2.42
2136
1620
1602
2.64
2326
1666
1642
2.86
2512
1.0
Bhp
Watts
1.33
1190
1.47
1310
1.52
1353
1.66
1473
1.80
1595
1.93
1709
2.14
1892
2.35
2076
2.59
2283
2.85
2504