Section Ii; Installation And Operation; Assembling; Gas Ballast - Agilent Technologies MS-301 Instruction Manual

High capacity rotary vane pumps
Table of Contents

Advertisement

ISTRUZIONI ORIGINALI

SECTION II

INSTALLATION AND OPERATION

Assembling

If the pump is supplied without any electrical mo-
tor, install a motor whose characteristics are the
same as stated on the technical sheet, construc-
tive form IM B5.
WARNING!
Check that the distance between the two coupling
halves is:
− Type 1: B = 3.5 ±1 mm (see figure below)
− Type 2: B = 3.5 ±1 mm (see figure below).
A
Type 1

Gas Ballast

Pumps of the MS series are fitted with a gas bal-
last valve in order to exhaust any water vapour
present in the rotor. When the pump operates with
the gas ballast open, please follow these instruc-
tions:
Position the selector switch in the flow direc-
tion (circuit is open).
The ultimate pressure in this kind of operation
is better than 0.7 mbar.
When water vapour has been removed and the
pump original conditions are to be reset:
Position the selector switch crossway with re-
spect to the flow (circuit is closed)
In this kind of operation the ultimate pressure
is better than 0.1 mbar.
B
Type 2
20/43
TECHNICAL INFORMATION
Closed position

Positioning

− The pump must be installed in a protected area
(see "SAFETY PRECAUTIONS").
− It must be fastened with support feet on hori-
zontal surface.
− It must be accessible for correct ands easy
maintenance, by respecting the minimum dis-
tances from possible obstructions (see follow-
ing figure and table).
A
B
Open position
D
C
87-900-136-01

Advertisement

Table of Contents