Physical Data - Bryant PREFERRED 265A Product Data

Preferred series heat pump with puron refrigerant
Hide thumbs Also See for PREFERRED 265A:
Table of Contents

Advertisement

UNIT SIZE SERIES
Operating Weight (lb)
Shipping Weight (lb)
Compressor Type
REFRIGERANT
Control
Charge (lb)
COND FAN
Air Discharge
Air Qty (CFM)
Motor HP
Motor RPM
COND COIL
Face Area (Sq ft)
Fins per In.
Rows
Circuits
VALVE CONNECT. (In. ID)
Vapor
Liquid
REFRIGERANT TUBES* (In. OD)
Vapor (0---80 Ft Tube Length)
Liquid (0---80 Ft Tube Length)
* For tubing sets between 80 ft. and 200 ft. horizontal or 20 ft. vertical differential (250 ft. Total Equivalent Length), consult the Long---Line Guideline.
Note: See unit Installation Instruction for proper installation.
VAPOR LINE SIZING AND COOLING CAPACITY LOSS
PURON 1- -STAGE HEAT PUMP APPLICATIONS
LONG LINE APPLICATION: An application is considered
"Long line" when the total equivalent tubing length exceeds 80
ft. or when there is more than 20 ft. vertical separation between
indoor and outdoor units. These applications require additional
accessories and system modifications for reliable system
operation. The maximum allowable total equivalent length is 250
ft. The maximum vertical separation is 200 ft. when outdoor unit
Acceptable
Liquid Line
Unit Nominal
Diameter OD
Size (Btuh)
(in.)
18000
3/8
1 ---Stage Puron
HP
24000
3/8
1 ---Stage Puron
HP
30000
1 ---Stage Puron
3/8
HP
36000
1 ---Stage Puron
3/8
HP
42000
3/8
1 ---Stage Puron
HP
48000
3/8
1 ---Stage Puron
HP
60000
1 ---Stage Puron
3/8
HP
Standard Length = 80 ft. or less total equivalent length
Applications in this area are long line. Accessories are required as shown recommended on Long Line Application Guidelines
Applications in this area may have height restrictions that limit allowable total equivalent length, when outdoor unit is below indoor unit See
Long Line Application Guidelines

PHYSICAL DATA

018---B
198
232
6.13
2595
1/10
800
16.26
20
1
4
5/8"
5/8"
Acceptable
Vapor Line
Standard Application
Diameters
OD (in.)
25
50
1/2
1
2
5/8
0
0
5/8
0
1
3/4
0
0
5/8
1
2
3/4
0
0
7/8
0
0
5/8
1
2
3/4
0
0
7/8
0
0
3/4
0
1
7/8
0
0
3/4
0
1
7/8
0
0
3/4
1
2
7/8
0
1
1 1/8
0
0
024---B
030---B
036---B
244
280
299
280
310
335
Scroll
Puron® (R--- 410A)
TXV (Puron Hard Shutoff)
10.4
12
14.8
Propeller Type, Direct Drive
Vertical
2595
3265
3265
1/10
1/5
1/5
800
800
800
18.3
20.33
24.4
20
20
20
1
1
2
5
6
5
5/8"
3/4"
3/4"
3/8"
5/8"
3/4"
3/4"
3/8"
is above indoor unit, and 80 ft. when the outdoor unit is below
the indoor unit. Refer to Accessory Usage Guideline below for
required accessories. See Long- -Line Application Guideline for
required piping and system modifications. Also, refer to the table
below for the acceptable vapor tube diameters based on the total
length to minimize the cooling capacity loss.
Cooling Capacity Loss (%)Total Equivalent Line Length (ft.)
Long Line Application Requires Accessories
80
80+
100
125
150
3
3
4
6
1
1
1
1
1
1
2
3
0
0
0
1
3
3
3
4
1
1
1
1
0
0
0
1
4
4
5
6
1
1
1
2
0
0
0
1
2
2
2
3
1
1
1
1
2
2
3
4
1
1
1
2
4
4
5
6
2
2
2
3
0
0
1
1
3
042---B
048---B
318
325
354
361
14.2
12.6
3265
3673
1/5
1/4
800
800
24.4
24.4
20
20
2
2
7
8
7/8"
7/8"
7/8"
7/8"
175
200
225
7
8
9
10
2
2
3
3
3
4
4
5
1
1
1
1
5
6
7
8
2
2
2
3
1
1
1
1
7
9
10
11
2
3
3
4
1
1
1
2
4
4
5
6
2
2
2
3
5
5
6
7
2
2
3
3
7
9
10
11
4
4
5
5
1
1
1
1
060---B
307
344
12.5
3673
1/4
800
22.4
20
2
9
7/8"
1--- 1/8"
250
12
3
6
2
9
3
1
13
4
2
6
3
8
4
12
6
2