Bryant 286BNC Product Data

Bryant 286BNC Product Data

Evolution 16 2-stage with puron refrigerant for coastal applications 2-5 nominal tons

Advertisement

Quick Links

286BNC
R
EVOLUTION
16 2- -STAGE HEAT PUMP
WITH PURONr REFRIGERANT FOR COASTAL APPLICATIONS
2 - - 5 NOMINAL TONS
Bryant's heat pumps with Puronr refrigerant provide a collection
of features unmatched by any other family of equipment. The
286BNC has been designed utilizing Bryant's Puronr refrigerant.
The environmentally sound refrigerant allows consumers to make a
responsible decision in the protection of the earth's ozone layer.
This product has been designed and manufactured to meet Energy
Starr criteria for energy efficiency when matched with appropriate
coil components. Refer to the combination ratings in the Product
Data for system combinations that meet Energy Starr guidelines.
NOTE: Ratings contained in this document are subject to
change at any time.
Always refer to the AHRI directory
(www.ahridirectory.org) for the most up- -to- -date ratings
information.

Product Data

Energy Efficiency
S
S
Sound
S
S
S
S
Comfort
S
Reliability
S
S
TM
S
S
S
S
S
S
S
S
Controls and Diagnostics
S
S
S
Durability
DuraGuard Plust protection package:
S
S
S
TuffCoatt Condenser Coil
S
S
Applications
S
INDUSTRY LEADING
FEATURES / BENEFITS
13.5 - - 17.0 SEER/11.0 - - 13.3 EER/8.0 - - 9.6 HSPF
Microtube Technologyt refrigeration system
Sound level as low as 69 dBA
Quiet mount split post compressor grommets
Compressor sound hood
8 pole PSC ball bearing outdoor condenser fan motor
System supports Evolution Controlt or standard 2- -stage
thermostat controls
Puronr refrigerant - - environmentally sound, won't deplete
the ozone layer and low lifetime service cost.
Front- -seating service valves
2- -stage scroll compressor
Internal pressure relief valve
Internal thermal overload
High pressure switch
Loss of charge switch
Filter drier
Balanced refrigeration system for maximum reliability
Crankcase heater standard
Evolutiont Control or 2- -Stage Thermostat
Utility Interface Connection
Enhanced diagnostics capability with Evolutiont Control
Solid, Durable sheet metal construction
Steel louver coil guard
2- -Sided, baked- -on, complete coverage, powder paint
Aluminum fin material is pre- -coated on both sides with a
corrosion protective epoxy phenolic thermoset coating.
Industry leading standard coastal warranty coverage
Long- -line - - up to 250 feet (76.2 m) total equivalent length.

Advertisement

loading

Summary of Contents for Bryant 286BNC

  • Page 1: Product Data

    Internal thermal overload High pressure switch Loss of charge switch Filter drier Bryant’s heat pumps with Puronr refrigerant provide a collection Balanced refrigeration system for maximum reliability of features unmatched by any other family of equipment. The Crankcase heater standard 286BNC has been designed utilizing Bryant’s Puronr refrigerant.
  • Page 2: Model Number Nomenclature

    MODEL NUMBER NOMENCLATURE Product Tier SEER Major Voltage Variations Cooling Capacity Open Open Open Series Family Series 2=HP 6 = 16 SEER B=Puron N= 208 ---230 ---1 C = Coastal 0=Not 0=Not 0=Not Evolution or 208/230 ---1 Defined Defined Defined Original Series Series...
  • Page 3: Physical Data

    PHYSICAL DATA Model 286BNC UNIT SIZE SERIES 024--- A 036--- A 048--- A 060--- A Operating Weight lb (kg) 310 (141) 310 (141) 314 (142) 368 (167) Shipping Weight lb (kg) 376 (171) 376 (171) 380 (172) 434 (197) Compressor Type...
  • Page 4: Refrigerant Piping Length Limitations

    REFRIGERANT PIPING LENGTH LIMITATIONS Maximum Line Lengths: The maximum allowable total equivalent length for heat pumps varies depending on the vertical separation. See the tables below for allowable lengths depending on whether the outdoor unit is on the same level, above or below the outdoor unit. Maximum Line Lengths for Heat Pump Applications MAXIMUM ACTUAL LENGTH MAXIMUM EQUIVALENT LENGTH{...
  • Page 5 ACCESSORIES KIT NUMBER KIT NAME 024--- A 036--- A 048--- A 060--- A KHALS0401LLS SOLENOID VALVE KHASS0606MPK* SNOW STAND KSAHS2301AAA HARD START KIT KSAHS2401AAA HARD START KIT KSAHS2501AAA HARD START KIT KSAHS2601AAA HARD START KIT KSASF0101AAA SUPPORT FEET KSASH2101COP SOUND BLANKET KSATX0201PUR KSATX0301PUR KSATX0401PUR...
  • Page 6: Accessory Usage Guideline

    ACCESSORY USAGE GUIDELINE REQUIRED FOR REQUIRED FOR Accessory SEA COAST APPLICATIONS LONG LINE APPLICATIONS* (Within 2 miles / 3.22 km) Accumulator Standard Standard Crankcase Heater Hard Shutoff TXV See Long --- Line Application Guideline Liquid Line Solenoid Valve Support Feet Recommended * For tubing line sets between 80 and 200 ft.
  • Page 7: Electrical Data

    AMPS 024--- A 52.0 12.7 16.4 48 (14.6) 45 (13.7) 036--- A 82.0 16.7 22.1 57 (17.4) 54 (16.4) 286BNC 208 ---230 ---1 048--- A 96.0 26.9 34.8 89 (27.1) 55 (16.8) 060--- A 118.0 23.0 30.1 103 (31.4) 63 (19.2) Permissible limits of the voltage range at which the unit will operate satisfactorily If wire is applied at ambient greater than 30_C, consult table 310 ---16 of the NEC (NFPA 70).
  • Page 12 Wall...
  • Page 58: Guide Specifications General

    GUIDE SPECIFICATIONS AIR- -COOLED, SPLIT- -SYSTEM HEAT PUMP 286BNC GENERAL 2 TO 5 NOMINAL TONS System Description Compressor Outdoor- -mounted, air- -cooled, split- -system heat pump unit — Compressor will be hermetically sealed. suitable for ground or rooftop installation. Unit consists of a —...
  • Page 59 SYSTEM DESIGN SUMMARY 1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01- -in. wc. 2. This product is qualified for low ambient cooling operation (below 55_F / 12.8_C) with an Evolution User Interface ONLY. 3.
  • Page 60 Catalog No. PDS286BNC ---01 EBryant Heating & Cooling Systems 7310 W. Morris St. Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 04/12 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Replaces: New...