AHA
— Adjustable Heat Anticipator
C
— Contactor, Compressor
CAP
— Capacitor
CC
— Cooling Compensator
CLO
— Compressor Lockout
COMP — Compressor Motor
D
— Diode
EC
— Enthalpy Control
ECON — Economizer
EPS
— Emergency Power Supply
EQUIP — Equipment
ER
— Economizer Relay
FPT
— Freeze-Protection Thermostat
FSS
— Filter-Status Switch
FU
— Fuse
GND
— Ground
GVR
— Gas Valve Relay
HPS
— High-Pressure Switch
HS
— Hall-Effect Sensor
HV
— High Voltage
I
— Ignitor
IDM
— Induced-Draft Motor
IFC
— Indoor (Evaporator) Fan Contactor
NOTES:
1. If any of the original wire furnished must be replaced, it must be replaced with Type 90 C wire or its equivalent.
2. Three-phase motors are protected under primary single-phasing conditions.
3. Thermostats: HH07AT170, 172
Subbase: HH93AZ176, 177, 178 and 179
4. Set heat anticipator at .14 amp for first stage and .14 amp for second stage.
5. Use copper conductors only.
6. TRAN is wired for 230 v unit. If unit is to be run with 208 v power supply, disconnect BLK wire from 230 v tap and
connect to 208 v tap (RED). Insulate end of 230 v tap.
TYPICAL WIRING SCHEMATIC (cont)
581B036-072 Typical Wiring Schematic and Component Arrangement
(208/230 V 3-Phase Unit Shown) (cont)
IFM
— Indoor (Evaporator) Fan Motor
IGC
— Integrated Gas Unit Controller
LED
— Light-Emitting Diode
LPS
— Low-Pressure/Loss-of-Charge Switch
LS
— Limit Switch
MGV
— Main Gas Valve
MTR
— Motor
OAT
— Outdoor-Air Thermostat
OFM
— Outdoor (Condenser) Fan Motor
OLR
— Overload
P
— Plug
PL
— Plug Assembly
QT
— Quadruple Terminal
R
— Relay
— Rollout Switch
RS
SAT
— Supply-Air Thermostat
SEN
— Sensor
SW1
— Switch Fully Open
SW2
— Switch Fully Closed
SW3
— Switch Minimum Vent Position
SW4
— Switch Maximum Vent Position
TC
— Thermostat-Cooling
LEGEND
56
TH
— Thermostat-Heating
TRAN — Transformer
Field Splice
Marked Wire
Terminal (Marked)
Terminal (Unmarked)
Terminal Block
Splice
Splice (Marked)
Factory Wiring
Field Control Wiring
Field Power Wiring
Accessory or Optional Wiring
To indicate common potential only.