581B090-150 STANDARD MOTOR (Units Without Electrical Convenience Outlet)
VOLTAGE
NOMINAL
UNIT
VOLTAGE
581B
(V-Ph-Hz)
Min
208/230-3-60
187
090
460-3-60
414
575-3-60
518
208/230-3-60
187
102
460-3-60
414
575-3-60
518
208/230-3-60
187
120
460-3-60
414
575-3-60
518
208/230-3-60
187
150
460-3-60
414
575-3-60
518
581B090-150 STANDARD MOTOR (Units With Electrical Convenience Outlet)
VOLTAGE
NOMINAL
UNIT
VOLTAGE
581B
(V-Ph-Hz)
Min
208/230-3-60
187
090
460-3-60
414
575-3-60
518
208/230-3-60
187
102
460-3-60
414
575-3-60
518
208/230-3-60
187
120
460-3-60
414
575-3-60
518
208/230-3-60
187
150
460-3-60
414
575-3-60
518
LEGEND
FLA
— Full Load Amps
HACR — Heating, Air Conditioning and Refrigeration
IFM
— Indoor (Evaporator) Fan Motor
LRA — Locked Rotor Amps
MCA — Minimum Circuit Amps
MOCP— Maximum Overcurrent Protection
NEC — National Electrical Code
OFM — Outdoor (Condenser) Fan Motor
RLA — Rated Load Amps
UL
— Underwriters' Laboratories
*Used to determine minimum disconnect per NEC.
†Fuse or HACR circuit breaker per NEC.
NOTES:
1. In compliance with NEC requirements for multimotor and combina-
tion load equipment (refer to NEC Articles 430 and 440), the overcur-
rent protective device for the unit shall be fuse or HACR breaker. The
UL, Canadian approved units may be fuse or circuit breaker.
2. Unbalanced 3-Phase Supply Voltage
Never operate a motor where a phase imbalance in supply voltage is
greater than 2%. Use the following formula to determine the percent
of voltage imbalance.
% Voltage imbalance
max voltage deviation from average voltage
= 100 x
average voltage
ELECTRICAL DATA (cont)
COMPRESSOR
RANGE
Max
RLA
LRA
254
12.4
88.0
508
6.4
44.0
632
4.8
34.0
254
15.0
99.0
508
8.2
49.5
632
5.8
40.0
254
18.9
125.0
508
9.0
62.5
632
7.1
50.0
254
19.0
156.0
508
9.0
70.0
632
7.4
54.0
COMPRESSOR
RANGE
Max
RLA
LRA
254
12.4
88.0
508
6.4
44.0
632
4.8
34.0
254
15.0
99.0
508
8.2
49.5
632
5.8
40.0
254
18.9
125.0
508
9.0
62.5
632
7.1
50.0
254
19.0
156.0
508
9.0
70.0
632
7.4
54.0
COMBUSTION
OFM
IFM
FAN MOTOR
FLA
FLA
FLA
1.4
7.5
.57
0.7
3.4
.30
0.7
3.4
.30
1.4
7.5
.57
0.7
3.4
.30
0.7
3.4
.30
1.4
10.6
.57
0.7
4.8
.30
0.7
4.8
.30
1.4
15.0
.57
0.7
7.4
.30
0.7
7.4
.30
COMBUSTION
OFM
IFM
FAN MOTOR
FLA
FLA
FLA
1.4
7.5
.57
0.7
3.4
.30
0.7
3.4
.30
1.4
7.5
.57
0.7
3.4
.30
0.7
3.4
.30
1.4
10.6
.57
0.7
4.8
.30
0.7
4.8
.30
1.4
15.0
.57
0.7
7.4
.30
0.7
7.4
.30
Example: Supply voltage is 460-3-60.
AB = 452 v
BC = 464 v
AC = 455 v
Average Voltage =
Determine maximum deviation from average voltage.
(AB) 457 – 452 = 5 v
(BC) 464 – 457 = 7 v
(AC) 457 – 455 = 2 v
Maximum deviation is 7 v.
Determine percent of voltage imbalance.
% Voltage Imbalance = 100 x
This amount of phase imbalance is satisfactory as it is below the maxi-
mum allowable 2%.
IMPORTANT: If the supply voltage phase imbalance is more than 2%,
contact your local electric utility company immediately.
47
POWER
SUPPLY
WITH OUTLET
MCA
MOCP
FLA
38.2/38.2
45/45†
40/40
19.2
25†
14.6
20†
44.1/44.1
50/50†
46/46
23.3
30†
16.9
20†
55.9/55.9
60/60†
59/59
26.5
30†
20.9
25†
60.6/60.6
70/70
64/64
29.1
35†
23.7
30†
POWER
SUPPLY
WITH OUTLET
MCA
MOCP
FLA
44.2/44.2
50/50†
46/46
21.9
25†
16.8
20†
50.1/50.1
60/60†
52/52
26.0
30†
19.1
25†
61.9/61.9
70/70
64/64
29.2
35†
23.1
25†
66.6/66.6
80/70
70/70
31.8
35†
25.9
30†
452 + 464 + 455
3
1371
=
3
= 457
7
457
= 1.53%
MINIMUM UNIT
DISCONNECT
SIZE*
LRA
242/242
20
121
16
95
264/264
24
132
18
107
341/341
28
171
22
136
426/426
31
197
25
154
MINIMUM UNIT
DISCONNECT
SIZE*
LRA
247/247
23
124
18
97
269/269
27
135
20
109
345/345
30
173
24
139
430/430
33
199
27
156