E. Before Lighting Appliance
Before operating this fireplace for the first time, it is rec-
ommended that a qualified service technician:
• Verify all shipping materials have been removed from
inside and/or underneath the firebox.
• Verify multi-purpose tool has been removed and is
available.
• Review proper placement of logs, glass media and
stones.
• Check the wiring.
• Check the air shutter adjustment.
• Ensure that there are no gas leaks.
• Verify Glass Seal Plate is properly installed. See Figure
3.6.
WARNING! Glass seal plate must be properly installed.
Risk of elevated component temps and carbon monox-
ide exposure.
• Ensure that the glass is sealed and in the proper position
and that the integral barrier is in place.
WARNING! Risk of Fire or Asphyxiation! DO NOT op-
erate fireplace with fixed glass assembly removed.
• Verify collar slide plate screw is attached see Figure 3.5.
Figure 3.5 Collar Slide Plate Screw Detail
10
BE SURE SLIDE
PLATE SCREW IS
FULLY TIGHTENED.