7-6. Inspection of Gear Oil

The oil gauge is located on the side of the gear
box.
1.On a level surface, check that the oil level
reaches the middle of the oil gauge.
2.Check underneath the machine for oil
leakage.

7-7. Supply of Gear Oil

Do not mix different types of oil.
Use BONNOC TS680 (or equivalent) as oil.
1.If the oil level is low, follow the steps below to supply oil.
[1]Open the oil filler cap, and then supply oil through the oil filling port until the oil level
reaches the middle of the oil gauge.
[2]Tighten the oil filler cap securely.
2.On a level surface, check if the oil level is at
the middle of the oil gauge. If necessary,
supply oil.
3.Check underneath the machine for oil
leakage.
− 19 −
Oil filler cap
Oil gauge
Oil filler cap
Oil gauge

7-8. Inspection of Universal Joint

1.Inspect the chain for damage, abnormal wear and so on.
2.Inspect the cover for cracks, damage, abnormal wear and so on.

7-9. Inspection of Oil Leakage

After approximately 50 hours of operation, some joints may be loosened and oil and grease
may leak.
Be sure to retighten the parts.
Check the bottom of the machine for oil and grease leakage.
Chain
Cover