MCZ CUTE AIR 8 M1 Use And Installation Manual page 46

Hide thumbs Also See for CUTE AIR 8 M1:
Table of Contents

Advertisement

29-ALARMS
A13
A14
A17
A21
SAFETY DEVICES
TRIP
A22
POP-UP
POP-UP
46
Electronic control unit overheating
Faulty air flow rate sensor
Blocked feed screw due to clogged pellets
or a foreign body
Open stove door
Open fuel loading hatch
Air pressure switch
Room probe anomaly
Disconnected Wi-Fi probe
Alarms
The structure is too hot because the product has been
used for too long at the maximum power or there is
poor ventilation. When the stove is sufficiently cold,
press button B on the control panel or OFF on the remote
control to cancel alarm A13. Once the alarm is cancelled,
the product can be switched on normally.
This alarm blocks the stove and can be reset from the
App. If the sensor is faulty, the alarm appears once
again. Contact an authorised service centre to have the
component replaced.
The feed screw is not unblocked even after the feed screw
unblocking procedure indicated by the software has been
carried out (rotating the gear motor in both directions).
Try to remove the pellets and/or foreign body with an
extractor or call an authorised service centre to perform
this operation.
Close the door
Close the hatch.
Lower the fuel level in the hopper.
Draught difficulties or clogged brazier.
Check whether the brazier is clogged by deposits and
clean it, if necessary.
Check and if necessary clean the smoke duct and air inlet.
Contact an authorised service centre to have the
component replaced.
Make sure the device has charged batteries
Replace the batteries and restart the device connection
procedure
From the App, it is possible to receive a message
regarding the alarms that cannot be reset from the App,
such as A01, A02, A03, A05, A21, but which can only be
reset from the stove's panel. After resetting the alarm
from the panel, reset the message from the App.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Thema air 8 m1

Table of Contents