23-OPERATION MENU
ECOSTOP
From the ECO STOP menu, it is possible to set and/or edit delayed activation (min) and Reignition hysteresis (C°).
ECO is an automatic mode with the only difference that if the set temperature is reached and remains so for the time (in minutes) that was
selected from the delayed activation drop-down menu (value ranging between 5 and 30 minutes), the product switches off and remains
in stand-by until the room temperature drops below the desired temperature (hysteresis frequency ranges between 2 and 5 minutes). The
product then switches back on again.
If the room is not sufficiently insulated, flame modulation does not allow the set temperature to
stay satisfied for the set time and the product will not switch off.
NOTE: It is recommended to use the ECO mode only in well-insulated rooms in order to prevent
start-up and shutdown from occurring within short periods of time.
32