Bryant DELUXE 11 SEER R-410A User Manual page 5

Deluxe 11 seer air conditioner with puron
Table of Contents

Advertisement

UNIT SIZE-SERIES
Operating Weight (Lb)
ELECTRICAL
Unit Volts—Hertz—Phase
Operating Voltage Range*
Compressor—Rated Load Amps
Locked Rotor Amps
Condenser Fan Motor—Full Load Amps
Min Unit Ampacity for Wire Sizing
Min Wire Size (60°C Copper) AWG†
Min Wire Size (75°C Copper) AWG†
Max Wire Length (Ft) (60°C Copper)‡
Max Wire Length (Ft) (75°C Copper)‡
Max Branch Circuit Fuse or
Circuit Breaker Size (Amps)
COMPRESSOR & REFRIGERANT
Compressor— Type
Manufacturer
Temperature & Current Protection
Refrigerant—Type
Amount (Lb)
CONDENSER COIL & FAN
Coil Face Area (Sq Ft)
Fins per In.—Rows—Circuits
Fan Motor—HP (PSC) & RPM
Volts—Hertz—Phase
Condenser Airflow (CFM)
OPTIONAL EQUIPMENT
Support Feet
Coastal Filter
Time Delay Relay
Cycle Protector
Crankcase Heater
Start Assist—Capacitor/Relay Type
Start Assist—PTC Type
TXV (Hard Shutoff)
Piston Body
Filter Drier (Suction Line) (RCD)
Evaporator Freeze Thermostat††
Liquid-Line Solenoid Valve
Winter Start Control††
Low-Ambient Pressure Switch
MotorMaster® Control**
Ball Bearing Fan Motor (RCD)
Thermostat—Auto Changeover,
Non-Programmable, °F/°C,
1-Stage Heat, 1-Stage Cool
Thermostat—Auto Changeover,
7-Day Programmable, °F/°C,
1-Stage Heat, 1-Stage Cool
Thermidistat™ Control—
Programmable Thermostat with Humidity Control
Builder's Thermostat—Manual Changeover,
Non-Programmable, °F/°C,
1-Stage Heat, 1-Stage Cool
Outdoor Air Temperature Sensor
Backplate for Non-Programmable Thermostat
Backplate for Programmable Thermostat
Backplate for Builder's Thermostat
Thermostat Conversion Kit (4 to 5 wire)—10 Pack
* Permissible limits of the voltage range at which the unit will operate satisfactorily. Operation outside these limits may result in unit failure.
† If wire is applied at ambient greater than 30°C (86°F), consult Table 310-16 of the NEC (ANSI/NFPA 70).
The ampacity of nonmetallic-sheathed cable (NM), trade name ROMEX, shall be that of 60°C (140°F) conductors, per the NEC (ANSI/NFPA 70) Article 336-26. If
other than uncoated (non-plated), 60 or 75°C (140 or 167°F) insulation, copper wire (solid wire for 10 AWG and smaller, stranded wire for larger than 10 AWG) is
used, consult applicable tables of the NEC (ANSI/NFPA 70).
‡ Length shown is as measured 1 way along wire path between unit and service panel for a voltage drop not to exceed 2%.
** Fan motor with ball bearings required.
†† See low-ambient controller Installation Instructions for application.
N/A — Not Applicable.
NOTE: Copper wire must be used from service disconnect to unit. All motors/compressors contain internal overload protection.
SPECIFICATIONS Continued
042-A
215
19.9
127.0
1.10
24.4
10
10
77
73
40
6.33
12.16
25—1—2
1/5 & 825
2800
KSAHS1501AAA
KSATX0301HSZ
HC38GE231
—5—
048-A
217
208/230-60-1
187-253
24.4
131.0
1.40
26.7
8
10
97
59
50
Scroll
Copeland
Internal Line Break
Puron® (R-410A)
6.83
12.16
25—1—2
1/4 & 1100
208/230-60-1
3400
KSASF0101AAA
KAACF0801MED
KAATD0101TDR
KSACY0101AAA
KAACH1201AAA
KAACS0201PTC
KSATX0401HSZ
KSAPX0101PIS
KH45LG141
KAAFT0101AAA
KAALS0201LLS
KAAWS0101AAA
KSALA0301410
32LT660004
HC40GE232
TSTATBBNAC01-B
TSTATBBPAC01-B
TSTATBBPRH01-B
TSTATBBBAC01-B
TSTATXXSEN01-B
TSTATXXNBP01
TSTATXXPBP01
TSTATXXBBP01
TSTATXXCNV10
060-A
278
30.1
172.0
1.40
35.9
8
8
80
76
60
7.93
18.3
25—1—3
1/4 & 1100
3400
KSAHS1601AAA
KSATX0501HSZ

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

591b