Bryant DELUXE 11 SEER R-410A User Manual page 22

Deluxe 11 seer air conditioner with puron
Table of Contents

Advertisement

EVAP
AIR
75
Capacity
Total
MBtuh†
CFM
EWB
Total Sens‡
Kw**
591BN060-A Outdoor Section With CC5A/CD5AW060 Indoor Section
72
69.22 36.58
4.95
67
64.38 44.16
4.89
1750
62
58.36 51.45
4.84
57
54.62 54.62
4.77
72
70.41 38.02
5.07
67
65.69 46.32
4.99
2000
62
59.82 54.78
4.94
57
57.09 57.09
4.92
72
71.30 38.92
5.18
67
66.69 48.23
5.10
2250
62
61.06 57.75
5.04
57
59.25 59.25
5.03
Indoor
Section
Size
CC5A/CD5AA
060
CC5A/CD5AW
060
CE3AA
060
CK3BA
060
CK5A/CK5BA
060
CK5A/CK5BT
060
CK5A/CK5BX
060
F(A,B)4AN(F,B,C)
060
FB4ANB
070
FC4BN(F,B)
060
FC4BNB
070
FG3AAA
060
FK4CNB
006
FV4ANB
006
FX4ANB
060
* Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per ARI standard 210/240-94. If additional tubing length and/or
indoor unit is located above outdoor unit, a slight variation in capacity may occur.
† Total and sensible capacities are net capacities. Blower motor heat has been subtracted.
‡ Sensible capacities shown are based on 80°F (27°C) entering air at the indoor coil. For sensible capacities at other than 80°F (27°C), deduct 835 Btuh
(245 kw) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80°F (27°C), or add 835 Btuh (245 kw) per 1000 CFM (480 L/S) of indoor coil air
per degree above 80°F (27°C). When the required data falls between the published data, interpolation may be performed.
** Unit kw is outdoor unit kilowatts only.
DETAILED COOLING CAPACITIES* Continued
CONDENSER ENTERING AIR TEMPERATURES °F
85
Capacity
Capacity
Total
MBtuh†
Sys
Sys
Total Sens‡
Kw**
Total Sens‡
66.19 35.29
5.48
62.78 33.88
61.20 42.74
5.40
57.80 41.24
55.10 49.85
5.35
51.71 48.16
52.25 52.25
5.27
49.61 49.61
67.22 36.67
5.59
63.69 35.21
62.45 44.98
5.51
59.00 43.56
56.52 53.20
5.47
53.02 51.35
54.55 54.55
5.43
51.94 51.94
67.96 37.56
5.70
64.36 36.12
63.44 46.97
5.62
59.94 45.63
57.76 56.12
5.56
54.11 54.11
56.71 56.71
5.56
53.92 53.92
Multipliers for Determining the Performance With Other Indoor Sections
Cooling
Capacity
Power
0.95
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.02
1.00
1.02
0.98
1.02
1.02
1.00
95
105
Capacity
Total
MBtuh†
MBtuh†
Sys
Kw**
Total Sens‡
6.04
58.99 32.38
5.97
54.15 39.67
5.89
48.08 46.29
5.82
46.91 46.91
6.15
59.83 33.63
6.08
55.22 42.01
6.03
49.22 49.22
6.00
49.04 49.04
6.25
60.44 34.53
6.19
55.98 44.11
6.13
50.87 50.87
6.13
50.89 50.89
Indoor
Section
0.97
COILS + 333(B,J)AV060100 VARIABLE SPEED FURNACE
1.00
CC5A/CD5AA
1.00
CC5A/CD5AW
1.00
CE3AA
1.00
CK3BA
1.00
CK5A/CK5BA
1.01
CK5A/CK5BT
1.04
CK5A/CK5BX
1.02
COILS + 333(B,J)AV060120 VARIABLE SPEED FURNACE
1.04
CC5A/CD5AA
1.02
CC5A/CD5AW
1.00
CE3AA
0.97
CK3BA
0.97
CK5A/CK5BA
1.02
CK5A/CK5BT
CK5A/CK5BX
—22—
115
Capacity
Total
Total
MBtuh†
Sys
Sys
Kw**
Total Sens‡
Kw**
Total Sens‡
6.64
54.84 30.79
7.28
50.05 28.81
6.59
50.11 37.96
7.23
45.63 36.09
6.47
44.11 44.11
7.08
40.86 40.86
6.43
43.95 43.95
7.07
40.88 40.88
6.76
55.55 31.86
7.40
50.53 29.71
6.69
50.99 40.29
7.32
46.36 38.32
6.60
45.93 45.93
7.25
42.82 42.82
6.59
45.95 45.95
7.25
42.84 42.84
6.86
56.03 32.73
7.50
50.83 30.44
6.78
51.64 42.39
7.42
46.91 40.31
6.75
47.74 47.74
7.40
44.19 44.19
6.75
47.76 47.76
7.40
44.21 44.21
Cooling
Size
Capacity
060
0.95
060
0.98
060
1.00
060
0.99
060
0.99
060
0.99
060
1.00
060
0.95
060
0.98
060
1.00
060
0.99
060
0.99
060
0.99
060
1.00
125
Capacity
Total
MBtuh†
Sys
Kw**
7.96
7.89
7.78
7.78
8.06
7.98
7.97
7.97
8.16
8.08
8.06
8.06
Power
0.96
0.96
0.97
0.96
0.96
0.96
0.96
0.97
0.97
0.98
0.97
0.97
0.97
0.97