Bryant 556A Fact Sheet

4 seer split-system air conditioner with r-410a data for preliminary use only

Advertisement

Quick Links

This product meets GREEN
As an ENERGY STAR
SEAL criteria for manufac-
Bryant Heating & Cooling Sys-
turing,
energy
efficiency,
tems has determined that this prod-
sound levels and packaging.
uct meets the ENERGY STAR
It contains no CFCs or
guidelines for energy efficiency.
HCFCs.
REGISTERED QUALITY SYSTEM
preliminary product fact sheet
14 SEER SPLIT-SYSTEM
AIR CONDITIONER WITH R-410A
DATA FOR PRELIMINARY USE ONLY
A97272
SM
Partner,
—1—
Cancels: New
The model 556A Air Conditioner uses the ozone-friendly refrigerant
R-410A. The unit is available in nominal sizes 024 through 042. The
unit features a copper tube, enhanced aluminum fin coil for a compact,
low-profile appearance with vertical air discharge.
FEATURES
• SEER of at least 14.0 with specified Bryant equipment
• AeroQuiet System
• Earth-friendly refrigerant R-410A
• High-pressure switch
• Low-pressure switch
• R-410A liquid-line filter drier
• Compressor sound hood
• Compressor start assist—PTC type
• Compressor plug
• Crankcase heater
• Copper tube aluminum fin coil
• External brass back seating service valves with sweat connections
• R-410A hard shutoff TXV
• Condenser coil grille
• Electric ground lug
LIMITED WARRANTY
• 1-year parts only warranty on all parts
• Additional 9-year warranty on compressor, no labor
556A
PF 556A.24.1
11-97

Advertisement

Table of Contents
loading

Summary of Contents for Bryant 556A

  • Page 1 HCFCs. REGISTERED QUALITY SYSTEM The model 556A Air Conditioner uses the ozone-friendly refrigerant R-410A. The unit is available in nominal sizes 024 through 042. The unit features a copper tube, enhanced aluminum fin coil for a compact, low-profile appearance with vertical air discharge.
  • Page 2 —2—...
  • Page 3: Metering Device

    † In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance. Use either the accessory Time-Delay Relay KAATD0101TDR or a furnace equipped with TDR. All Bryant furnaces are equipped with TDR except for the 394HAD.
  • Page 4: Specifications

    UNIT SIZE-SERIES Operating Weight (Lb) ELECTRICAL Unit Volts—Hertz—Phase Operating Voltage Range* Compressor— Rated Load Amps Locked Rotor Amps Condenser Fan Motor—Full Load Amps Minimum Unit Ampacity for Wire Sizing Minimum Wire Size (60°C Copper) (AWG)† Minimum Wire Size (75°C Copper) (AWG)† Maximum Wire Length (60°C) (Ft)‡...
  • Page 5: Accessory Usage Guideline

    ACCESSORY Crankcase Heater Evaporator Freeze Thermostat Winter Start Control Accumulator Compressor Start Assist Capacitor and Relay Low-Ambient Controller, MotorMaster® Control, Low-Ambient Pressure Switch Wind Baffle See Low-Ambient Instructions Coastal Filter Support Feet Liquid-Line Solenoid Valve Hard Shutoff TXV Ball Bearing Fan Motor * For tubing line sets between 50 and 175 ft, refer to the Application Guideline and Service Manual for Residential Split-System Air Conditioners and Heat Pumps using R-410A Refrigerant.
  • Page 6 R-410A—QUICK REFERENCE GUIDE R-410A refrigerant operates at 50-70 percent higher pressures than R-22. Be sure that servicing equipment and replacement • components are designed to operate with R-410A. R-410A refrigerant cylinders are rose colored. • R-410A refrigerant cylinders have a dip tube which allows liquid to flow out of cylinder in upright position. •...
  • Page 7: Matched System

    AIR CONDITIONER FURNACE COIL 1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01-in. wc. 2. Minimum outdoor operating air temperature without low-ambient operation accessory is 55°F (12.8°C). 3. Maximum outdoor operating air temperature is 125°F (51.7°C) 4.
  • Page 8: Service Training

    Course descriptions and schedules are in our catalog. CALL FOR FREE CATALOG 1-800-962-9212 [ ] Packaged Service Training © 1997 Bryant Heating & Cooling Systems 7310 W. Morris St. Indianapolis, IN 46231 SERVICE TRAINING • Maintenance • Operating Sequence [ ] Classroom Service Training —8—...

Table of Contents