Segment Display Configurations - Chauvet LEG-3000 User Manual

250w moving light fixture
Hide thumbs Also See for LEG-3000:
Table of Contents

Advertisement

{    } – P an /T ilt co n t ro l ch ann el re- a ss ig n
This function will re-position the pan & tilt control channels to start at DMX value number 1.
F
UNCTION

{    } - Shut t e r aut o - cl os e
The shutter will close momentarily during the color, gobo or prism changes. The shutter will re-open
once the color, gobo or prism has reached its position.
F
UNCTION

{    } - Co lo r w h ee l lin e ar / st e p b eh av io r
This function set to "Off" will allow the linear or gradual progression for the selection of a color on the
color wheel. It gives the user the ability to stop the wheel in between colors. The default "On" setting
advances the color wheel full or complete steps.
F
UNCTION

{    } – M anu al f o cu s
The user can use this function to manually adjust the focus. This feature can be used in conjunction
with operating the demo show or during maintenance and alignment.
F
UNCTION


Segment Display Configurations

{    } - Di sp l a y Au t o- of f
The led display can be set to automatically turn off during normal operations.
F
UNCTION

{    } - R ev e r se t h e dis pl a y
You can rotate the display 180° so that it becomes easier to read when the fixture is positioned
upside down.
F
UNCTION

LEG-3000 Manual
S
T
N
ET
O
OTES
Off
Default
Pan/Tilt re-assign to channel
On
1-4
S
T
N
ET
O
OTES
Off
Normal
On
Shutter auto-close
S
T
N
ET
O
OTES
Off
Linear progression
On
Step advance
S
T
N
ET
O
OTES
Off
Normal
On
Adjust focus
S
T
N
ET
O
OTES
Display Auto-Off, press any
Off
key to turn on display
On
Always on
S
T
N
ET
O
OTES
Off
Normal display view
On
Reverse the display