Operation Control; Cooling Operation - Panasonic CS-PC12TKF Service Manual

Table of Contents

Advertisement

12. Operation Control

12.1 Cooling Operation

Cooling operation can be set using remote control.
This operation is applied to cool down the room temperature to the setting temperature set on the remote control.
The remote control setting temperature, which takes the reading of intake air temperature sensor, can be
adjusted from 16°C to 30°C.
During cooling operation, the compressor will stop and restart as shown in figure below:
Remote control
setting temperature
12.1.1
Cooling Operation Time Diagram (For PC12TKF)
Intake Air
Temperature
Time Frame
Compressor
Indoor Fan
Outdoor Fan
Operation LED
<Description of operation>
a -b, g - h
d - g, s - u
h - o
q - u
Intake air
temperature
Compressor ON
Compressor-OFF
a b c d e f g h i j k l m n o p q r s t u v w x y z
Compressor-ON level
1.5°C
Compressor-OFF level
(Setting Temperature)
1'
: Minimum 60 seconds forced operation
: Minimum 3 minutes restart control (Time Delay Safety Control)
: Maximum 7 minutes time save control
: Freeze Prevention control
1.5°C higher than setting temperature
10°C
Indoor
Heat Exchanger
Temperature
2°C
3 min
1'
7'
40
1'
4'
min 3'
Operation
Stop

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs-pc18tkfCs-pc24tkfCu-pc12tkfCu-pc18tkfCu-pc24tkf

Table of Contents