Step 5: Write DDC data
1. Configuration should be as Fig. 24. And press OK.
2.Access factory. Mode
Step 1 : Select the source "PC" and then turn off LCD-TV.
Step 2 : [Push "power " button and then push the "VOL- " and "VOL+"
buttons at the same time immediately and hold it] about five seconds
then release all buttons.
Press "menu"button and bring up factory mode indication
3. Click
(Write EDID) icon from the tool bar to write DDC data.
Step 6: Save DDC data
Sometimes, you may need to save DDC data as a text file for using
in other IC chip. To save DDC data, follow the steps below:
1. Click
(Save) icon (or click "file"-> "save as") from the tool bar
And give a file name as shown in Fig. 25.
The file type is EDID46 file (*.ddc) which can be open in WordPad.
By using WordPad, the texts of DDC data & table (128 bytes, hex
code) can be modified. If DDC TEXTS & HEX Table are completely
correct, it can be saved as .ddc flie to re-load it into DDC IC for DDC
Data application.
Save
2.
Click
.
Step 7: Exit DDC program
Pull down the File menu and select Exit as shown in Fig. 26.
Edid45.1
DDC Instructions
Fig. 24
Fig. 25
Fig. 26