Main PCB assembly & KEY PCB assembly
WARNING
• DISCONNET power supply before servicing.
• Replace all panels and parts before
operating.
• RECONNECT all grounding devices.
- Failure to do so can result in severe personal injury, death
or electrical shock.
1. After insert 4 springs into 4 supporters of PCB base,
Insert housing of KEY PCB assembly into CN41 wafer of Main PCB assembly.
2. Insert connector of main harness to CN1 of interface PCB
3. Place KEY PCB assembly into PCB Base Mold.
LGE Internal Use Only
ASSEMBLY
• Be careful when you work on the Cooktop
handling the sheet metal part.
- 59 -
CAUTION
Copyright © 2008 LG Electronics. Inc. All right reserved.